Evidence map›Paper›PMID 36970223›Full record

ArticleKidney medicine2023

Serum Creatinine and Tacrolimus Assessment With VAMS Finger-Prick Microsampling: A Diagnostic Test Study.

Carla E Scuderi, Suzanne L Parker, Margaret Jacks, George T John, Brett McWhinney, Jacobus Ungerer, Andrew J Mallett, Helen G Healy, Jason A Roberts, Christine E Staatz

Open access · goldAbstract read
In one paragraph

Article in Kidney medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 3 countries.

Carla E ScuderiKidney Health Service, Metro North Hospital and Health Service, Brisbane, Australia.
Suzanne L ParkerQ Centre for Clinical Research, Faculty of Medicine, The University of Queensland, Brisbane, Australia.
Margaret JacksKidney Health Service, Metro North Hospital and Health Service, Brisbane, Australia.
George T JohnKidney Health Service, Metro North Hospital and Health Service, Brisbane, Australia.
Brett McWhinneyPathology Queensland, Brisbane, Australia.
Jacobus UngererPathology Queensland, Brisbane, Australia.
Andrew J MallettFaculty of Medicine, The University of Queensland, Brisbane, Australia.
Helen G HealyKidney Health Service, Metro North Hospital and Health Service, Brisbane, Australia.
Jason A RobertsQ Centre for Clinical Research, Faculty of Medicine, The University of Queensland, Brisbane, Australia.
Christine E StaatzSchool of Pharmacy, University of Queensland, Brisbane, Australia.
The University of Queensland · AUQueensland Health · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rationale & Objective: Kidney transplant recipients require frequent venipunctures. Microsampling methods that use a finger-prick draw of capillary blood, like volumetric absorptive microsamplers (VAMS), have the potential to reduce the pain, inconvenience, and volume of blood loss associated with venipuncture. This study aimed to provide diagnostic accuracy using VAMS for measurement of tacrolimus and creatinine compared to gold standard venous blood in adult kidney transplant recipients. Study Design: Diagnostic test study. Prospective blood samples for measurement of tacrolimus and creatinine were collected using Mitra VAMS and venipuncture immediately before and 2 hours after tacrolimus dosing. Setting & Participants: A convenience sample of 40 adult kidney transplant participants in the outpatient setting. Tests Compared: Method comparison was assessed by Passing-Bablok regression and Bland-Altman analysis. The predictive performance of VAMS measurement compared to venipuncture was also assessed through estimation of the median prediction error and median absolute percentage prediction error. Results: A total of 74 tacrolimus samples and 70 creatinine samples were analyzed from 40 participants. Passing-Bablok regression showed a systematic difference between VAMS and venipuncture when measuring tacrolimus and creatinine with a slope of 1.08 (95% CI, 1.03-1.13) and a slope of 0.65 (95% CI, 0.6-0.7), respectively. These values were then corrected for the systematic difference. When used for Bland-Altman analysis, corrected values of tacrolimus and creatinine showed a bias of -0.1 μg/L and 0.04 mg/dL, respectively. Tacrolimus (corrected) and creatinine (corrected) microsampling values when compared to corresponding venipuncture values met median prediction error and median absolute percentage prediction error predefined acceptability limits of <15%. Limitations: This study was conducted in a controlled environment using a trained nurse to collect VAMS samples. Conclusions: In this study, VAMS was used to reliably measured tacrolimus and creatinine. This represents a clear opportunity for more frequent and less invasive sampling for patients.

Indexed as

Creatininekidney transplanttacrolimustherapeutic drug monitoringvolumetric absorptive microsampling

Identifiers

PMID36970223
PMCPMC10034504
OpenAlexW4319231773

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.