ArticleKidney medicine2023
Serum Creatinine and Tacrolimus Assessment With VAMS Finger-Prick Microsampling: A Diagnostic Test Study.
Article in Kidney medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 9 citations in OpenAlex.
- Volumetric Microsampling for Patient-Centric Therapeutic Drug Monitoring in Clinical Pharmacology: A Scoping Review.Journal of clinical pharmacology · 2026Article
- An Offline SPE-LC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Cyclosporine A, Kynurenine, Tryptophan, and Creatinine Using Volumetric Absorptive Microsampling Device Mitra.Therapeutic drug monitoring · 2025Article
- Targeted and untargeted metabolomics and lipidomics in dried blood microsampling: Recent applications and perspectives.Analytical science advances · 2024Review
- A miniaturized sample preparation method for routine elemental determination in whole blood using volumetric absorptive micro-sampling by ICP-QQQ.Analytical and bioanalytical chemistry · 2024Article
- Self-Management of Kidney Transplant Recipients Research: A Comprehensive Bibliometric Analysis.Journal of multidisciplinary healthcare · 2024Review
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rationale & Objective: Kidney transplant recipients require frequent venipunctures. Microsampling methods that use a finger-prick draw of capillary blood, like volumetric absorptive microsamplers (VAMS), have the potential to reduce the pain, inconvenience, and volume of blood loss associated with venipuncture. This study aimed to provide diagnostic accuracy using VAMS for measurement of tacrolimus and creatinine compared to gold standard venous blood in adult kidney transplant recipients. Study Design: Diagnostic test study. Prospective blood samples for measurement of tacrolimus and creatinine were collected using Mitra VAMS and venipuncture immediately before and 2 hours after tacrolimus dosing. Setting & Participants: A convenience sample of 40 adult kidney transplant participants in the outpatient setting. Tests Compared: Method comparison was assessed by Passing-Bablok regression and Bland-Altman analysis. The predictive performance of VAMS measurement compared to venipuncture was also assessed through estimation of the median prediction error and median absolute percentage prediction error. Results: A total of 74 tacrolimus samples and 70 creatinine samples were analyzed from 40 participants. Passing-Bablok regression showed a systematic difference between VAMS and venipuncture when measuring tacrolimus and creatinine with a slope of 1.08 (95% CI, 1.03-1.13) and a slope of 0.65 (95% CI, 0.6-0.7), respectively. These values were then corrected for the systematic difference. When used for Bland-Altman analysis, corrected values of tacrolimus and creatinine showed a bias of -0.1 μg/L and 0.04 mg/dL, respectively. Tacrolimus (corrected) and creatinine (corrected) microsampling values when compared to corresponding venipuncture values met median prediction error and median absolute percentage prediction error predefined acceptability limits of <15%. Limitations: This study was conducted in a controlled environment using a trained nurse to collect VAMS samples. Conclusions: In this study, VAMS was used to reliably measured tacrolimus and creatinine. This represents a clear opportunity for more frequent and less invasive sampling for patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.