Evidence map›Paper›PMID 36967394›Full record

ArticleEuropean radiology experimental2023

Photon-counting CT of elbow joint fractures: image quality in a simulated post-trauma setting with off-center positioning.

Lena Sonnow, Nigar Salimova, Lea Behrendt, Frank K Wacker, Marcus Örgel, Jochen Plagge, Friederike Weidemann

Open access · goldFull text read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.8field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Lena SonnowDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany. sonnow.lena@mh-hannover.de.ORCID 0000-0001-5006-7260
Nigar SalimovaDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Lea BehrendtDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Frank K WackerDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Marcus ÖrgelDepartment of Trauma Surgery, Hannover Medical School, Hannover, Germany.
Jochen PlaggeDepartment of Orthopedic Surgery, Hannover Medical School at Diakovere Annastift, Hannover, Germany.
Friederike WeidemannDepartment of Trauma Surgery, Hannover Medical School, Hannover, Germany.
Medizinische Hochschule Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPhoton-counting detector computed tomography (PCD-CT) has the potential to provide superior image quality compared to energy-integrating detector computed tomography (EID-CT). We compared the two systems for elbow imaging in off-center arm positioning, 90° flexion, and cast fixation in a simulated post-trauma setting.

methodsThe institutional review board approved the study protocol. In a cadaver study, an olecranon fracture was artificially created in ten whole arm specimens. Two different scanning positions were evaluated: (a) arm overhead; and (b) arm on top of the abdomen of a whole-body phantom. The ultra-high resolution mode with three dose protocols and two reconstruction kernels was applied. Two blinded radiologists independently evaluated fracture and trabecular bone delineation. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and cortical sharpness measurements were performed. Cohen κ correlations, Mann-Whitney U and Wilcoxon signed rank tests were used. A p value lower than 0.05 was considered statistically significant.

resultsDose-equivalent PCD-CT scans were rated better for fracture and trabecular bone evaluation (p < 0.001). SNR, CNR, and cortical sharpness were higher for all diagnostic (Br76) PCD-CT images (p < 0.001). The arm position had less effect on image quality in the PCD-CT compared to the EID-CT. The use of a sharp bone kernel (Br89) improved image quality ratings for PCD-CT. In the low-dose scan mode, PCD-CT resulted in more diagnostic scans (75%) compared to EID-CT (19%).

conclusionsPCD-CT provided superior objective and subjective image quality for fracture and trabecular bone structures delineation of the elbow compared to EID-CT in a typical post-trauma setting. KEY POINTS: • Photon-counting detector computed tomography (PCD-CT) preserved high image quality in elbow imaging with off-center positions. • PCD-CT was advantageous for bone evaluation in trauma elbows. • PCD-CT ultra-high-resolution mode and very sharp reconstruction kernels facilitated higher image quality.

Indexed as

Elbow JointCadaverHumansPhantoms, ImagingPhotonsTomography, X-Ray ComputedCadaverElbowMusculoskeletal systemOlecranon processTomography (x-ray computed)

Identifiers

PMID36967394
PMCPMC10040392
OpenAlexW4360979262

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read36
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.