Evidence map›Paper›PMID 36964769›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2023

Choose the appropriate implantation position of the Femoral Neck System in the femoral neck: a finite-element analysis.

Ximu Kuang, Guojian Jian, Desheng Xie, Xiaolin Chen, Haoyuan Liu

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ximu KuangDepartment of Orthopedics, Chenggong Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.ORCID http://orcid.org/0000-0003-0350-0505
Guojian JianDepartment of Orthopedics, Chenggong Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.
Desheng XieDepartment of Orthopedics, Chenggong Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.
Xiaolin ChenDepartment of Orthopedics, Chenggong Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.
Haoyuan LiuDepartment of Orthopedics, Chenggong Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China. xm174@126.com.

Funding

Xiamen Superior Sub-construction project of the Arthroscopic minimally invasive Orthopedics department. Xiamen Key Specialty construction project of Traumatic Orthopedics department 2018296
6 · The paper itself

Abstract

purposeThere is no specific literature on the best implantation position of the Femoral Neck System (FNS) for treating Pauwels type III femoral neck fracture in young adults.

methodsUse finite-element analysis to compare the mechanical properties of implantation positions: FNS in the central position, FNS in the low position, and FNS in the low position combined with cannulated screw (CS). The CT data of the femur were imported into the mimics20.0 to obtain the three-dimensional model of the femur; imported into geomagic2017 and SolidWorks 2017 for optimizations; models of FNS and CS are built on the basis of the device manuals. Grouping is as follows: FNS group, FNS-LOW group, and FNS-CS group. Assemble and import them into abaques6.14 for load application. The displacement distribution and von Mises Stress value of them were compared.

resultsOn femoral stability and stress distribution, the FNS-CS group performs best, followed by the FNS-LOW group, and finally FNS group. The FNS-LOW group has an improvement over the FNS group but not by much.

conclusionIn operations, when the implantation position of the central guide wire is not at the center of the femoral neck but slightly lower, it is recommended not to adjust the wire repeatedly in pursuit of the center position; for femoral neck fractures that are extremely unstable at the fracture end or require revision, the insertion strategy of FNS in the low position combined with CS can be adopted to obtain better fixation effects.

Indexed as

Femoral Neck FracturesFemur NeckBiomechanical PhenomenaBone ScrewsFemurFracture Fixation, InternalHumansFemoral neck fractureFemoral Neck SystemFinite-element analysisImplantation positionYoung adults

Identifiers

PMID36964769
PMCPMC10449665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.