Comparison of Four Mechanical Insufflation-Exsufflation Devices: Effect of Simulated Airway Collapse on Cough Peak Flow.

Nicolas Terzi, Isabelle Vaugier, Claude Guérin, Hélène Prigent, Ghilas Boussaid, Karl Leroux, Mathieu Delorme, Frédéric Lofaso, Bruno Louis

Open access · greenAbstract read
In one paragraph

Article in Respiratory care, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 1 country.

Nicolas TerziCentre Hospitalier Universitaire Grenoble Alpes, Médecine Intensive Réanimation, INSERM, Université Grenoble-Alpes, Grenoble, France. nicolas.terzi@chu-rennes.fr.
Isabelle VaugierClinical Investigation Centre 1429, APHP, Hôpital Raymond-Poincaré, Garches, France.
Claude GuérinMedecine Intensive-Réanimation, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France; Université de Lyon, Lyon, France; and Institut Mondor de Recherches Biomédicales, INSERM 955 CNRS ERL 7000, Créteil, France.
Hélène PrigentINSERM U1179, END-ICAP, Université de Versailles-Saint Quentin, University of Paris-Saclay, Montigny-le-Bretonneux, France; and Service de Physiologie et Explorations Fonctionnelles, GH Paris Ile de France Ouest-Site Raymond Poincaré-AP-HP, Garches, France.
Ghilas BoussaidUniversité Paris-Saclay, UVSQ, ERPHAN, Versailles, France.
Karl LerouxASV Santé, 125, Avenue Louis Roche, Gennevilliers, France.
Mathieu DelormeUniversité Paris-Saclay, UVSQ, ERPHAN, Versailles, France; Université de Lyon, Lyon, France; and Institut Mondor de Recherches Biomédicales, INSERM 955 CNRS ERL 7000, Créteil, France.
Frédéric LofasoService de Physiologie et Explorations Fonctionnelles, GH Paris Ile de France Ouest-Site Raymond Poincaré-AP-HP, Garches, France; and Université Paris-Saclay, UVSQ, ERPHAN, Versailles, France.
Bruno LouisInstitut Mondor de Recherches Biomédicales, INSERM 955 CNRS ERL 7000, Créteil, France.
Inserm · FRUniversité Claude Bernard Lyon 1 · FRUniversité de Versailles Saint-Quentin-en-Yvelines · FRCentre National de la Recherche Scientifique · FRDépartement Santé Animale · FRHôpital Raymond-Poincaré · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMechanical insufflation-exsufflation (MI-E) devices are used to improve airway clearance in individuals with acute respiratory failure. Some MI-E devices measure cough peak flow (CPF) during MI-E to optimize pressure adjustments. The aim was to compare CPF and effective cough volume (ECV: volume expired/coughed > 3 L/s) measurements between 4 MI-E devices under simulated conditions of stable versus collapsed airway.

methodsFour MI-E devices were tested on the bench. Each device was connected via a standard circuit to a collapsible tube placed in an airtight chamber that was attached to a lung model with adjustable compliance and resistance. Pressure was measured upstream and downstream the collapsing tube; air flow was measured between the chamber and the lung model. Each device was tested in 2 conditions: collapse condition (0 cm H

resultsCPF values measured at the tracheal level and ECV values differed between devices for each inspiratory/expiratory pressure in the collapse and no-collapse conditions (

conclusionsCPF values differed significantly across MI-E devices, highlighting limitation(s) of using only CPF values to determine cough effectiveness. In simulated of airway collapse, CPF increased at the mouth, whereas it decreased at the tracheal level.

Indexed as

CoughInsufflationHumansLungPeak Expiratory Flow RateRespiration, Artificialairway collapsecough assistancemechanical in-exsufflationpeak expiratory flowupper airway

Identifiers

PMID36963968
PMCPMC10173116
OpenAlexW4360820253

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.