ArticlePLOS global public health2023
Feasibility and usability of a very low-cost bubble continuous positive airway pressure device including oxygen blenders in a Ugandan level two newborn unit.
Article in PLOS global public health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05462509 (Feasibility of Use of the PATH bCPAP Kit Including Oxygen Blenders in a Neonatal Population in Uganda), which is not on this map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Feasibility of Use of the PATH bCPAP Kit Including Oxygen Blenders in a Neonatal Population in Uganda
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.
- The Care of Preterm and Term Newborns with Respiratory Conditions: A Systematic Synthesis of Evidence from Low- and Middle-Income Countries.Neonatology · 2025Pooled it
- Birth asphyxia outcomes and associated factors among newborns admitted to a tertiary hospital in Eastern Uganda: A prospective cohort study.BMC pregnancy and childbirth · 2025Article
- The novel LESS (low-cost entrainment syringe system) OFrontiers in pediatrics · 2024Article
- Outborn newborns drive birth asphyxia mortality rates-An 8 year analysis at a rural level two nursery in Uganda.PLOS global public health · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 5 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPreterm birth and resulting respiratory failure is a leading cause of newborn death- the majority of which occur in resource-constrained settings and could be prevented with bubble continuous positive airway pressure (bCPAP). Commercialized devices are expensive, however, and sites commonly use improvised devices utilizing 100% oxygen which can cause blindness. To address this, PATH and a multidisciplinary team developed a very low-cost bCPAP device including fixed-ratio oxygen blenders.
objectiveWe assessed feasibility of use of the device on neonatal patients as well as the usability and acceptability of the device by healthcare workers. This study did not evaluate device effectiveness.
methodsThe study took place in a Ugandan level two unit. Neonates with respiratory failure were treated with the bCPAP device. Prospective data were collected through observation as well as likert-style scales and interviews with healthcare workers. Data were analyzed using frequencies, means and standard deviation and interviews via a descriptive coding method. Retrospectively registered via ClinicalTrials.gov number NCT05462509.
resultsFourteen neonates were treated with the bCPAP device in October-December 2021. Patients were born onsite (57%), with median weight of 1.3 kg (IQR 1-1.8). Median treatment length was 2.5 days (IQR 2-6). bCPAP was stopped due to: improvement (83%) and death (17%). All patients experienced episodes of saturations >95%. Median time for device set up: 15 minutes (IQR 12-18) and changing the blender: 15 seconds (IQR 12-27). After initial device use, 9 out of 9 nurses report the set-up as well as blender use was "easy" and their overall satisfaction with the device was 8.5/10 (IQR 6.5-9.5). Interview themes included the appreciation for the ability to administer less than 100% oxygen, desire to continue use of the device, and a desire for additional blenders.
conclusionsIn facilities otherwise using 100% oxygen, use of the bCPAP device including oxygen blenders is feasible and acceptable to healthcare workers.
trial registrationClinicalTrials.gov, Identifier NCT05462509.
Identifiers
What OpenQuestion holds
Registered trials