Evidence map›Paper›PMID 36961662›Full record

ArticleOphthalmology and therapy2023

Design and Validation of a Novel Smartphone-Based Visual Acuity Test: The K-VA Test.

Vasileios Karampatakis, Diamantis Almaliotis, Persefoni Talimtzi, Stavroula Almpanidou

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Ophthalmology and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05184036 (Development of an ICT Platform-Awareness System for the Support of Low Vision), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05184036 active not recruitingnot on this map

Development of an ICT Platform-Awareness System for the Support of Low Vision

TypeobservationalSponsorAristotle University Of ThessalonikiRan2018 to 2025Enrolled500ConditionsLow Vision Digital AssistanceArmsLow Vision
3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Validation and evaluation of visual acuity and contrast sensitivity with a new digital device: OPTOTAB®.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Vasileios KarampatakisLaboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Diamantis AlmaliotisLaboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Persefoni TalimtziLaboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Stavroula AlmpanidouLaboratory of Experimental Ophthalmology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece. stavalmp@gmail.com.ORCID http://orcid.org/0000-0002-7666-3527
Aristotle University of Thessaloniki · GR

Funding

This research has been co-financed by the European Union and Greek national funds through the Operational Program Competitiveness, Entrepreneurship and Innovation, under the call RESEARCH - CREATE - INNOVATE (project code: T1EDK-03742). T1EDK-03742
6 · The paper itself

Abstract

introductionVisual acuity (VA) testing is a critical screening examination for the assessment of visual function. This study describes the development and validation of a smartphone-based VA test: the K-VA test.

methodsA total of 171 patients with various ocular diseases were examined in our outpatient unit at Aristotle University of Thessaloniki, School of Medicine in Greece. Participants underwent VA examination using the standard Early Treatment Diabetic Retinopathy Study (ETDRS) charts and the K-VA smartphone-based test. The K-VA test was performed by participants themselves. The Bland-Altman method was employed to assess the agreement between the ETDRS charts and the new test for the examination of VA at 1 m and 40 cm. Test-retest reliability was also calculated. A questionnaire regarding the participants' feedback on the K-VA test was completed.

resultsNo significant bias was observed between the gold standard ETDRS charts and the K-VA test measurements. The mean difference (95% limits of agreement, LoA) between the K-VA test at 1 m and the ETDRS chart at 4 m was -0.006 (95% LoA -0.129 to 0.117) logarithm of the minimal angle of resolution (logMAR). The agreement of the K-VA test at 40 cm with the near ETDRS chart was also high with a mean difference of -0.007 (95% LoA -0.105 to 0.090) logMAR. Test-retest reliability was found to be high with a mean difference of 0.003 (95% LoA -0.045 to 0.033) logMAR and 0.005 (95% LoA -0.065 to 0.076) logMAR for the K-VA test at 1 m and 40 cm, respectively. A total of 97 participants answered the questionnaire and 71 (73.2%) stated that the test was easy to very easy to use for self-performance.

conclusionsThe study demonstrated that the K-VA application performed well compared with the ETDRS charts and provides reliable and repeatable measurements of VA across a wide range of VA.

Indexed as

ETDRSMobile applicationsSmartphonesTelemedicineVisual acuityVisual impairment

Identifiers

PMID36961662
PMCPMC10037403
OpenAlexW4360810237

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390