Evidence map›Paper›PMID 36960616›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2023

Sacral injury and influencing factors after ultrasonic ablation of uterine fibroids ≤30 mm from the sacrum

An-Qi Zheng, Jin-Yun Chen, Zhi-Bo Xiao, Rong Zhang, Jin Bai

Open access · goldAbstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

An-Qi ZhengUltrasound in Medicine and Engineering, State Key Laboratory, Chongqing, China.ORCID 0000-0001-9793-6929
Jin-Yun ChenUltrasound in Medicine and Engineering, State Key Laboratory, Chongqing, China.ORCID 0000-0002-6818-7145
Zhi-Bo XiaoDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID 0000-0001-7650-7463
Rong ZhangUltrasound in Medicine and Engineering, State Key Laboratory, Chongqing, China.ORCID 0000-00002-1889-7210
Jin BaiUltrasound in Medicine and Engineering, State Key Laboratory, Chongqing, China.ORCID 0000-0002-7959-5048
First Affiliated Hospital of Chongqing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo study sacral injuries and influencing factors after ultrasonic ablation of uterine fibroids no more than 30 mm from the sacrum.

methodsA total of 406 patients with uterine fibroids who underwent percutaneous ultrasound ablation were analyzed retrospectively. All patients underwent contrast-enhanced magnetic resonance imaging (MRI) scans before and after high-intensity focused ultrasound. The abnormal signal intensity (low signal intensity on T1WI and high signal intensity on T2WI) on the postoperative MRIs was indicative of a sacral injury. The patients were divided into a sacrum injury group and a sacrum non-injury group. The relationship between fibroid characteristics, ultrasound ablation parameters, and injury was analyzed using univariate and multivariate analyses.

resultsThere were 139 cases of sacral injury (34.24%). When the distance from the fibroid's dorsal side to the sacrum was 0-10 mm, the risk assessment showed that the danger of sacral injury increased by 1.85 times and 3.03 times compared with that at a distance of 11-20 or 21-30 mm. Furthermore, the risk of sacral injury increased by 1.89 times and 3.23 times when the therapeutic dose (TD) of a fibroid was >500 KJ compared with that of a fibroid with TD= 250-500 KJ and <250 KJ.

conclusionA distance of 10 mm or less and a TD of >500 KJ were significantly correlated with sacral injury. The distance from the fibroid's dorsal side to the sacrum and the TD were the main causes of injury to the sacrum. A distance of 10 mm or less and a TD of >500 KJ carried higher injury risks, while a distance of 21-30 mm and a TD of <250 KJ were the most appropriate circumstances to reduce the risk of sacral injury.

Indexed as

High-Intensity Focused Ultrasound AblationLeiomyomaUterine NeoplasmsFemaleHumansMagnetic Resonance ImagingRetrospective StudiesSacrumTreatment OutcomeHigh-intensity focused ultrasound (HIFU)magnetic resonance imagingsacrum injuryultrasound ablationuterine fibroids

Identifiers

PMID36960616
PMCPMC10679587
OpenAlexW4315703383

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.