Evidence map›Paper›PMID 36960598›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2023

Advanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation

Jung Han Hwang, Jin Mo Kang, Suyoung Park, So Hyun Park, Jeong Ho Kim, Ki Hyun Lee, Ji Hoon Shin, Seong Yong Pak

Abstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jung Han HwangDepartment of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.ORCID 0000-0002-0872-0956
Jin Mo KangDepartment of Surgery, Gachon University College of Medicine, Incheon, South Korea.ORCID 0000-0002-1477-9778
Suyoung ParkDepartment of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.ORCID 0000-0001-9688-3239
So Hyun ParkDepartment of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.ORCID 0000-0001-9935-2863
Jeong Ho KimDepartment of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.ORCID 0000-0002-1404-2821
Ki Hyun LeeDepartment of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.ORCID 0000-0002-1372-4281
Ji Hoon ShinDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea.ORCID 0000-0001-6598-9049
Seong Yong PakDepartment of Biomedical Engineering, University of Ulsan College of Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, Seoul, South Korea.ORCID 0000-0001-6598-9049

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the image quality of lower extremity computed tomography angiography (LE-CTA) using a reconstruction algorithm for monoenergetic images (MEIs) to evaluate peripheral arterial disease (PAD) at different kiloelectron volt (keV) levels.

methodsA total of 146 consecutive patients who underwent LE-CTA on a dual-energy scanner to obtain MEIs at 40, 50, 60, 70, and 80 keV were included. The overall image quality, segmental image quality of the arteries and PAD segments, venous contamination, and metal artifacts from prostheses, which may compromise quality, were analyzed.

resultsThe mean overall image quality of each MEI was 2.9 ± 0.7, 3.6 ± 0.6, 3.9 ± 0.3, 4.0 ± 0.2, and 4.0 ± 0.2 from 40 to 80 keV, respectively. The segmental image quality gradually increased from 40 to 70-80 keV until reaching its highest value. Among 295 PAD segments in 68 patients, 40 (13.6%) were scored at 1-2 at 40 keV and 13 (4.4%) were scored at 2 at 50 keV, indicating unsatisfactory image quality due to the indistinguishability between high-contrast areas and arterial calcifications. The segments exhibiting metal artifacts and venous contamination were reduced at 70-80 keV (2.6 ± 1.2, 2.7 ± 0.5) compared with at 40 keV (2.4 ± 1.1, 2.5 ± 0.7).

conclusionThe LE-CTA method using a reconstruction algorithm for MEIs at 70-80 keV can enhance the image quality for PAD evaluation and improve mitigate venous contamination and metal artifacts.

Indexed as

Peripheral Arterial DiseaseRadiography, Dual-Energy Scanned ProjectionAlgorithmsArtifactsComputed Tomography AngiographyHumansLower ExtremityRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSignal-To-Noise RatioArtifactatherosclerosiscomputed tomography angiographyperipheral arterial diseaseradiation dosage

Identifiers

PMID36960598
PMCPMC10679588

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.