Evidence map›Paper›PMID 36959409›Full record

ArticleEJNMMI physics2023

QCard-NM: Developing a semiautomatic segmentation method for quantitative analysis of the right ventricle in non-gated myocardial perfusion SPECT imaging.

Seyed Mohammad Entezarmahdi, Reza Faghihi, Mehran Yazdi, Negar Shahamiri, Parham Geramifar, Mahdi Haghighatafshar

Open access · goldFull text read
In one paragraph

Article in EJNMMI physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0).Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Seyed Mohammad EntezarmahdiNuclear Engineering Department, Shiraz University, Shiraz, Iran.
Reza FaghihiNuclear Engineering Department, Shiraz University, Shiraz, Iran. faghihir@shirazu.ac.ir.ORCID http://orcid.org/0000-0003-3238-6887
Mehran YazdiSchool of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran.
Negar ShahamiriNuclear Medicine and Molecular Imaging Research Center, Namazi Teaching Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
Parham GeramifarResearch Center for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Mahdi HaghighatafsharNuclear Medicine and Molecular Imaging Research Center, Namazi Teaching Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
Shiraz University · IRShiraz University of Medical Sciences · IRTehran University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecent studies have shown that the right ventricular (RV) quantitative analysis in myocardial perfusion imaging (MPI) SPECT can be beneficial in the diagnosis of many cardiopulmonary diseases. This study proposes a new algorithm for right ventricular 3D segmentation and quantification.

methodsThe proposed Quantitative Cardiac analysis in Nuclear Medicine imaging (QCard-NM) algorithm provides RV myocardial surface estimation and creates myocardial contour using an iterative 3D model fitting method. The founded contour is then used for quantitative RV analysis. The proposed method was assessed using various patient datasets and digital phantoms. First, the physician's manually drawn contours were compared to the QCard-NM RV segmentation using the Dice similarity coefficient (DSC). Second, using repeated MPI scans, the QCard-NM's repeatability was evaluated and compared with the QPS (quantitative perfusion SPECT) algorithm. Third, the bias of the calculated RV cavity volume was analyzed using 31 digital phantoms using the QCard-NM and QPS algorithms. Fourth, the ability of QCard-NM analysis to diagnose coronary artery diseases was assessed in 60 patients referred for both MPI and coronary angiography.

resultsThe average DSC value was 0.83 in the first dataset. In the second dataset, the coefficient of repeatability of the calculated RV volume between two repeated scans was 13.57 and 43.41 ml for the QCard-NM and QPS, respectively. In the phantom study, the mean absolute percentage errors for the calculated cavity volume were 22.6% and 42.2% for the QCard-NM and QPS, respectively. RV quantitative analysis using QCard-NM in detecting patients with severe left coronary system stenosis and/or three-vessel diseases achieved a fair performance with the area under the ROC curve of 0.77.

conclusionA novel model-based iterative method for RV segmentation task in non-gated MPI SPECT is proposed. The precision, accuracy, and consistency of the proposed method are demonstrated by various validation techniques. We believe this preliminary study could lead to developing a framework for improving the diagnosis of cardiopulmonary diseases using RV quantitative analysis in MPI SPECT.

Indexed as

MPI SPECTQuantitative analysisRight ventricleSegmentation

Identifiers

PMID36959409
PMCPMC10036722
OpenAlexW4360609278

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read89
table measurements read1
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.