Development of a dynamic motion platform with two independent drive systems for radiotherapy.

Masahide Saito, Hideyuki Kawakami, Toshihiro Suzuki, Hidekazu Suzuki, Koji Ueda, Hikaru Nemoto, Naoki Sano, Hiroshi Onishi

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Masahide SaitoDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.ORCID https://orcid.org/0000-0002-8636-4045
Hideyuki KawakamiAPEX medical Inc., Tokyo, Japan.
Toshihiro SuzukiDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.ORCID https://orcid.org/0000-0003-0414-5218
Hidekazu SuzukiDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.
Koji UedaDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.
Hikaru NemotoDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.ORCID https://orcid.org/0000-0001-6540-2906
Naoki SanoDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.
Hiroshi OnishiDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.
University of Yamanashi · JPApex Medical Technologies (United States) · USUniversity of Yamanashi Hospital · JP

Funding

JSPS KAKENHI 22K15823
6 · The paper itself

Abstract

backgroundThere are some motion platforms for radiotherapy quality assurance. However, no platform with two drive systems that can move along three axes is available. PURPOSE: The purpose of this study is to develop a dynamic motion platform with two drive systems capable of three-axis motion and to evaluate its motion performance.

methodsThe developed moving platform had two drive systems that use the same equipment. Each axis of the platform used can support a maximum load of 10 kg. The motors for moving the platform in each direction are capable of a drive stroke up to 40 mm. The drive speed is 30 mm/s at maximum load fluctuation. To evaluate the static positional accuracy of this system with an arbitrary input movement, the XYZ position of each axis was measured using a coordinate measuring machine operating from 0 to 40 mm at 10 mm intervals. In addition, the accuracy of dynamic motion was verified with Sine waveform inputs of different patterns to the three axes for approximately 60 s, and they were compared with the resulting detected signals by SyncTrax.

resultsThe two drive systems were successfully operated on three axes by using independent control systems. For static position, the accuracies were within 0.2 mm, 0.05 mm, and 0.14 mm for lateral, longitudinal, and vertical directions, respectively. For dynamic motion, the mean absolute errors in the X, Y, and Z axes between the platform inputs and SyncTrax detected signals were 0.14 ± 0.10 mm, 0.16 ± 0.12 mm, and 0.16 ± 0.11 mm, respectively.

conclusionsA new dynamic platform for radiation therapy with two drive systems capable of three-axis motion was developed, and the positional accuracy of the drive axes was confirmed to be less than 0.2 mm.

Indexed as

MovementHumansMotionPhantoms, Imaginglung cancermotion phantommotion trackingradiotherapytwo drive system

Identifiers

PMID36951306
PMCPMC10161022
OpenAlexW4360599612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.