Evidence map›Paper›PMID 36950590›Full record

ArticleHeliyon2023

Measuring sound velocity based on acoustic resonance using multiple narrow band transducers.

Na Li, Zihao Chen, Jiejun Zhu, Mi Hyun Choi, Jin Yang, Zhen Yuan, Lei Sun, Chunlong Fei, Zhihai Qiu

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 4 countries.

Na LiSchool of Microelectronics, Xidian University, Xi'an; Guangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Zihao ChenSchool of Microelectronics, Xidian University, Xi'an; Guangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Jiejun ZhuGuangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Mi Hyun ChoiDepartment of Bioengineering, Stanford University, CA, USA.
Jin YangGuangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Zhen YuanFaculty of Health Sciences, Centre for Cognitive and Brain Sciences, University of Macau, Macau SAR China.
Lei SunDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, PR China.
Chunlong FeiSchool of Microelectronics, Xidian University, Xi'an; Guangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Zhihai QiuSchool of Microelectronics, Xidian University, Xi'an; Guangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong 519031, China.
Xidian University · CNGuangdong Polytechnic of Science and Technology · CNHong Kong Polytechnic University · HKStanford University · USTianjin University · CNUniversity of Macau · MO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The sound velocity in a medium is closely related to its material properties, including its composition, structure, density, pressure, and temperature. Various methods have been developed to determine the sound velocity through materials. Among them, a strategy based on ultrasound resonance frequency has been most widely used due to the simplicity. However, it requires a transducer with a wide bandwidth to cover enough resonance frequencies to perform the consequent calculations. In this paper, we develop a resonance method for measuring sound velocity, using multi-frequency narrow-band transducers breaking through the limitation of transducer bandwidth on the utilization of the resonance method. We use different transducers at different center frequencies and with different bandwidth to measure the sound velocity in 100-μm and 400-μm thick steel pieces. The measurement results of different combinations are in good agreement, verifying that the use of multi-frequency narrow-band transducer combinations. Given that most therapeutic transducers have a narrow bandwidth, this method can be used during intracranial ultrasound stimulation to optimize targeting by non-invasively measuring the sound velocity in the skull, especially at thinner locations.

Indexed as

Multiple frequenciesMultiple ultrasound transducersResonance frequencySound velocity measurement

Identifiers

PMID36950590
PMCPMC10025888
OpenAlexW4322722903

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.