Evidence map›Paper›PMID 36950019›Full record

ArticleJournal of biomedical optics2023

Speed-resolved perfusion imaging using multi-exposure laser speckle contrast imaging and machine learning.

Martin Hultman, Marcus Larsson, Tomas Strömberg, Ingemar Fredriksson

Registry-linked trialOpen access · goldFull text read
In one paragraph

Article in Journal of biomedical optics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06009939 (Microvascular Sex and Age-related Day-to-day Variability in Healthy Subjects), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06009939 completednot on this map

Microvascular Sex and Age-related Day-to-day Variability in Healthy Subjects

TypeobservationalSponsorVårdcentralen ÅbyRan2023 to 2023Enrolled48ConditionsHealthy SubjectsArmsOcclusion of the circulation in the arm and foot
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Martin HultmanLinköping University, Department of Biomedical Engineering, Linköping, Sweden.ORCID 0000-0001-5912-3281
Marcus LarssonLinköping University, Department of Biomedical Engineering, Linköping, Sweden.ORCID 0000-0001-6385-6760
Tomas StrömbergLinköping University, Department of Biomedical Engineering, Linköping, Sweden.ORCID 0000-0002-7299-891X
Ingemar FredrikssonLinköping University, Department of Biomedical Engineering, Linköping, Sweden.ORCID 0000-0002-3454-6576
Linköping University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Laser speckle contrast imaging (LSCI) gives a relative measure of microcirculatory perfusion. However, due to the limited information in single-exposure LSCI, models are inaccurate for skin tissue due to complex effects from e.g. static and dynamic scatterers, multiple Doppler shifts, and the speed-distribution of blood. It has been demonstrated how to account for these effects in laser Doppler flowmetry (LDF) using inverse Monte Carlo (MC) algorithms. This allows for a speed-resolved perfusion measure in absolute units %RBC × mm/s, improving the physiological interpretation of the data. Until now, this has been limited to a single-point LDF technique but recent advances in multi-exposure LSCI (MELSCI) enable the analysis in an imaging modality. Aim: To present a method for speed-resolved perfusion imaging in absolute units %RBC × mm/s, computed from multi-exposure speckle contrast images. Approach: An artificial neural network (ANN) was trained on a large simulated dataset of multi-exposure contrast values and corresponding speed-resolved perfusion. The dataset was generated using MC simulations of photon transport in randomized skin models covering a wide range of physiologically relevant geometrical and optical tissue properties. The ANN was evaluated on in vivo data sets captured during an occlusion provocation. Results: Speed-resolved perfusion was estimated in the three speed intervals 0 to Conclusions: The ANN, trained on modeled data, calculates speed-resolved perfusion in absolute units from multi-exposure speckle contrast. This method facilitates the physiological interpretation of measurements using MELSCI and may increase the clinical impact of the technique.

Indexed as

Laser Speckle Contrast ImagingMachine LearningBlood Flow VelocityLaser-Doppler FlowmetryMicrocirculationPerfusion ImagingRegional Blood Flowartificial neural networksblood flowmicrocirculationmulti-exposure laser speckle contrast imaging

Identifiers

PMID36950019
PMCPMC10027009
OpenAlexW4327936186

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read24
table measurements read6
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.