ArticleBMC medical imaging2023
Tile-based microscopic image processing for malaria screening using a deep learning approach.
Article in BMC medical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Deep learning applications in parasite microscopy: A scoping review.PLoS neglected tropical diseases · 2026Article
- Intelligent automation cognitive system for accurate malaria diagnosis using digital blood smears.PloS one · 2026Article
- Leveraging MobileNetV2 and deep learning innovation for high accuracy Plasmodium Vivax detection in blood smears.Saudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society · 2025Article
- Artificial Intelligence in Biomedical Sciences: A Scoping Review.British journal of biomedical science · 2025Article
- An optimised YOLOv4 deep learning model for efficient malarial cell detection in thin blood smear images.Parasites & vectors · 2024Article
- Microscopic parasite malaria classification using best feature selection based on generalized normal distribution optimization.PeerJ. Computer science · 2024Article
- AIDMAN: An AI-based object detection system for malaria diagnosis from smartphone thin-blood-smear images.Patterns (New York, N.Y.) · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundManual microscopic examination remains the golden standard for malaria diagnosis. But it is laborious, and pathologists with experience are needed for accurate diagnosis. The need for computer-aided diagnosis methods is driven by the enormous workload and difficulties associated with manual microscopy based examination. While the importance of computer-aided diagnosis is increasing at an enormous pace, fostered by the advancement of deep learning algorithms, there are still challenges in detecting small objects such as malaria parasites in microscopic images of blood films. The state-of-the-art (SOTA) deep learning-based object detection models are inefficient in detecting small objects accurately because they are underrepresented on benchmark datasets. The performance of these models is affected by the loss of detailed spatial information due to in-network feature map downscaling. This is due to the fact that the SOTA models cannot directly process high-resolution images due to their low-resolution network input layer.
methodsIn this study, an efficient and robust tile-based image processing method is proposed to enhance the performance of malaria parasites detection SOTA models. Three variants of YOLOV4-based object detectors are adopted considering their detection accuracy and speed. These models were trained using tiles generated from 1780 high-resolution P. falciparum-infected thick smear microscopic images. The tiling of high-resolution images improves the performance of the object detection models. The detection accuracy and the generalization capability of these models have been evaluated using three datasets acquired from different regions.
resultsThe best-performing model using the proposed tile-based approach outperforms the baseline method significantly (Recall, [95.3%] vs [57%] and Average Precision, [87.1%] vs [76%]). Furthermore, the proposed method has outperformed the existing approaches that used different machine learning techniques evaluated on similar datasets.
conclusionsThe experimental results show that the proposed method significantly improves P. falciparum detection from thick smear microscopic images while maintaining real-time detection speed. Furthermore, the proposed method has the potential to assist and reduce the workload of laboratory technicians in malaria-endemic remote areas of developing countries where there is a critical skill gap and a shortage of experts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.