ArticleTexas Heart Institute journal2023
Sustained Lumen Area by Paclitaxel-Coated Balloon Following Rotational Atherectomy for Napkin-Ring Left Main Trunk Ostial Lesion.
Article in Texas Heart Institute journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 citations in OpenAlex.
- Observation of patency rates in patients with arteriovenous fistula stenosis treated with paclitaxel-coated high-pressure balloon angioplasty.Langenbeck's archives of surgery · 2026Trial
- Clinical expert consensus document on rotational atherectomy from the Japanese association of cardiovascular intervention and therapeutics: update 2026.Cardiovascular intervention and therapeutics · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Late lumen enlargement after percutaneous coronary intervention (PCI) with drug-coated balloon has contributed to good clinical results. However, late lumen enlargement with drug-coated balloon following rotational atherectomy has not been well reported. This report describes a case of calcified napkin-ring ostial lesion at the left main trunk that showed a sustained lumen area after PCI with drug-coated balloon following rotational atherectomy. An 85-year-old female patient was admitted to the hospital with dyspnea. Echocardiography showed hypokinesis in the anteroseptal and inferior walls. Electrocardiograph-gated cardiac computed tomography showed a calcified ostial lesion in the left main trunk. Invasive angiography of the coronary artery showed severe stenosis in the left main trunk ostium. Percutaneous coronary intervention was performed with a drug-coated balloon after rotational atherectomy. The minimal lumen area measured by intravascular ultrasound grew mildly from 4.09 to 4.17 mm2 immediately after PCI. Follow-up angiography and intravascular ultrasound performed after 6 months showed that the minimal lumen area in the left main trunk ostium was further enlarged from 4.17 to 4.69 mm2. The presence of sustained lumen area after PCI with drug-coated balloon following rotational atherectomy for a napkin-ring left main trunk ostial lesion was confirmed. This case demonstrates sustained lumen area after drug-coated balloon following rotational atherectomy in the left main trunk ostium, improving the patient's chest symptom. Hence, drug-coated balloon after rotational atherectomy may be an option for complex stent sites, such as the left main trunk ostium in geriatric patients and sites with highly calcified lesions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.