Evidence map›Paper›PMID 36944583›Full record

Observational studyActa obstetricia et gynecologica Scandinavica2023

Effectiveness of ambulatory non-invasive fetal electrocardiography: impact of maternal and fetal characteristics.

Becky Liu, Basky Thilaganathan, Amar Bhide

Registry-linked trialAbstract readObservational Study
In one paragraph

Observational study in Acta obstetricia et gynecologica Scandinavica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04941534 (AMBulatory Fetal ECG Monitoring in High Risk Pregnancies), which is not on this map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04941534 completednot on this map

AMBulatory Fetal ECG Monitoring in High Risk Pregnancies

TypeobservationalSponsorBiorithm Pte LtdRan2021 to 2022Enrolled100ConditionsPregnancy
3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Antenatal Noninvasive Fetal Electrocardiography: A Literature Review.Maternal-fetal medicine (Wolters Kluwer Health, Inc.) · 2024
    Review
  5. Article
  6. Article
  7. Observational
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Becky LiuFetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK.ORCID 0000-0002-4968-8294
Basky ThilaganathanFetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK.
Amar BhideFetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK.ORCID 0000-0003-2393-7501

Funding

Biorithm Pte Ltd N/A
6 · The paper itself

Abstract

introductionNon-invasive fetal electrocardiography (NIFECG) has potential benefits over the computerized cardiotocography (cCTG) that may permit its development in remote fetal heart-rate monitoring. Our study aims to compare signal quality and heart-rate detection from a novel self-applicable NIFECG monitor against the cCTG, and evaluate the impact of maternal and fetal characteristics on both devices. MATERIAL AND

methodsThis prospective observational study took place in a university hospital in London. Women with a singleton pregnancy from 28 + 0 weeks' gestation presenting for cCTG were eligible. Concurrent monitoring with both NIFECG and cCTG were performed for up to 60 minutes. Post-processing of NIFECG produced signal loss, computed in both 0.25 (E240)- and 3.75 (E16)-second epochs, and fetal heart-rate and maternal heart-rate values. cCTG signal loss was calculated in 3.75-second epochs. Accuracy and precision analysis of 0.25-second epochal fetal heart-rate and maternal heart-rate were compared between the two devices. Multiple regression analyses were performed to assess the impact of maternal and fetal characteristics on signal loss. CLINICALTRIALS: gov Identifier: NCT04941534.

results285 women underwent concurrent monitoring. For fetal heart-rate, mean bias, precision and 95% limits of agreement were 0.1 beats per minute (bpm), 4.5 bpm and -8.7 bpm to 8.8 bpm, respectively. For maternal heart-rate, these results were -0.4 bpm, 3.3 bpm and -7.0 to 6.2 bpm, respectively. Median NIFECG E240 and E16 signal loss was 32.0% (interquartile range [IQR] 6.5%-68.5%) and 17.3% (IQR 1.8%-49.0%), respectively. E16 cCTG signal loss was 1.0% (IQR 0.0%-3.0%). For NIFECG, gestational age was negatively associated with signal loss (beta = -2.91, 95% CI -3.69 to -2.12, P < 0.001). Increased body mass index, fetal movements and lower gestational age were all associated with cCTG signal loss (beta = 0.30, 95% CI 0.17-0.43, P < 0.001; beta = 0.03, 95% CI 0.01-0.05, P = 0.014; and beta = -0.28, 95% CI -0.51 to -0.05, P = 0.017, respectively).

conclusionsAlthough NIFECG is complicated by higher signal loss, it does not appear to be influenced by increased body mass index or fetal movement. NIFECG signal loss varies according to method of computation, and standards of signal acceptability need to be defined according to the ability of the device to produce clinically reliable physiological indices. The high accuracy of heart-rate indices is promising for NIFECG usage in the remote setting.

Indexed as

CardiotocographyFetusElectrocardiographyFemaleFetal MonitoringGestational AgeHeart Rate, FetalHumansPregnancyambulatory monitoringcomputerized cardiotocographyfetal heart rate monitoringnon-invasive fetal electrocardiographysignal losssignal quality

Identifiers

PMID36944583
PMCPMC10072254

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.