Evidence map›Paper›PMID 36944293›Full record

ArticleJournal of biomechanics2023

Effect of polyester-based artificial tendons on movement biomechanics: A preliminary in vivo study.

Patrick T Hall, Caleb Stubbs, Alisha P Pedersen, Caroline Billings, Stacy M Stephenson, Cheryl B Greenacre, David E Anderson, Dustin L Crouch

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Patrick T HallDepartment of Mechanical, Aerospace, and Biomedical Engineering, Tickle College of Engineering, University of Tennessee, 1512 Middle Drive, Knoxville, TN 37966, United States; Exponent, 3440 Market Street, Suite 600, Philadelphia, PA 19104, United States.
Caleb StubbsDepartment of Mechanical, Aerospace, and Biomedical Engineering, Tickle College of Engineering, University of Tennessee, 1512 Middle Drive, Knoxville, TN 37966, United States.
Alisha P PedersenDepartment of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, United States.
Caroline BillingsDepartment of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, United States.
Stacy M StephensonDivision of Plastic & Reconstructive Surgery, Department of Surgery, University of Tennessee Graduate School of Medicine, 1924 Alcoa Highway, Knoxville, TN 37920, United States.
Cheryl B GreenacreDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, United States.
David E AndersonDepartment of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Tennessee, 2407 River Drive, Knoxville, TN 37996, United States.
Dustin L CrouchDepartment of Mechanical, Aerospace, and Biomedical Engineering, Tickle College of Engineering, University of Tennessee, 1512 Middle Drive, Knoxville, TN 37966, United States. Electronic address: dustin.crouch@utk.edu.
University of Tennessee at Knoxville · USAlcoa (United States) · USExponent (United States) · US

Funding

Interdisciplinary Engineering Career Development Center in Movement and Rehabilitation SciencesK12HD073945 · NICHD · NORTHWESTERN UNIVERSITY AT CHICAGO · PI DEWALD, JULIUS P, REINKENSMEYER, DAVID JAY · 2012 to 2021
$7.9M
NICHD NIH HHS K12 HD073945
6 · The paper itself

Abstract

Artificial tendons may be valuable clinical devices for replacing damaged or missing biological tendons. In this preliminary study, we quantified the effect of polyester-suture-based artificial tendons on movement biomechanics. New Zealand White rabbits underwent surgical replacement of either the Achilles (n = 2) or tibialis cranialis (TC, n = 2) biological tendons with artificial tendons. Once pre-surgery and weekly from 2 to 6 weeks post-surgery, we quantified hindlimb kinematics and ground contact pressures during the stance phase of hopping gait. Post-surgical movement biomechanics were either consistent or improved over time in both groups. However, the Achilles group had greater overall biomechanical and muscle deficits than the TC group. In the TC group, at 6 weeks post-surgery, foot angles were about 10° greater than those in healthy controls during the first 30 % of stance. At 6 weeks post-surgery, the Achilles group exhibited lesser (i.e., more dorsiflexed) ankle angles (minimum angle = 31.5 ± 9.4°) and vertical ground reaction forces (37.4 ± 2.6 %BW) during stance than those in healthy controls (65.0 ± 11.2° and 50.2 ± 8.3 %BW, respectively). Future studies are needed to quantify long-term biomechanical function with artificial tendons, the effect of artificial tendons on muscle function and structure, and the effect of formal rehabilitation.

Indexed as

Achilles TendonFootAnimalsAnkleBiomechanical PhenomenaGaitRabbitsAnimalKinematicsOrthopedicsPressureProsthesis

Identifiers

PMID36944293
PMCPMC10150316
OpenAlexW4323322551

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.