Evidence map›Paper›PMID 36943929›Full record

ArticleCirculation. Cardiovascular interventions2023

Transcatheter Aortic Valve Replacement in Large Annuli Valves With the Supra-Annular, Self-Expandable Evolut Platform in a Real-World Registry.

Luis Augusto P Dallan, Gilbert Tang, John K Forrest, Michael J Reardon, Wilson Y Szeto, Susheel K Kodali, Cristian Baeza, Ruth Eisenberg, Guilherme F Attizzani

Abstract read
In one paragraph

Article in Circulation. Cardiovascular interventions, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. TAVR in Male Patients With Large Aortic Valve Annuli: A Propensity-Matched Analysis of Balloon-Expandable Versus Self-Expanding Valves.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Impact of prosthesis oversizing on clinical outcomes of transcatheter aortic valve implantation using a self-expandable Evolut R valve.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Luis Augusto P DallanHarrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, OH (L.A.P.D., C.B., G.F.A.).ORCID 0000-0002-8122-6647
Gilbert TangDepartments of Internal Medicine and Surgery, Mount Sinai Beth Israel, New York (G.T.).ORCID 0000-0001-7219-990X
John K ForrestDepartments of Internal Medicine and Surgery Yale University School of Medicine, New Haven, CT (J.K.F.).ORCID 0000-0003-4079-3482
Michael J ReardonDepartment of Cardiothoracic Surgery, Methodist DeBakey Heart and Vascular Center, Houston Methodist, Houston, TX (M.J.R.).ORCID 0000-0002-2880-6132
Wilson Y SzetoUniversity of Pennsylvania School of Medicine, Philadelphia (W.Y.S.).
Susheel K KodaliStructural Heart & Valve Center, New York Presbyterian/Columbia University Medical Center, New York (S.K.K.).
Cristian BaezaHarrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, OH (L.A.P.D., C.B., G.F.A.).ORCID 0000-0003-2001-332X
Ruth EisenbergStatistical Services, Medtronic, Mounds View, MN (R.E.).
Guilherme F AttizzaniHarrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, OH (L.A.P.D., C.B., G.F.A.).ORCID 0000-0001-9233-1242

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTranscatheter aortic valve replacement is approved for treatment of patients with severe aortic stenosis across the spectrum of risk. While considering broader indications for use, transcatheter aortic valve replacement in large native annuli has become increasingly important.

methodsPatients with tricuspid aortic stenosis undergoing transcatheter aortic valve replacement using the Evolut R or Evolut PRO+ 34 mm valves (Medtronic, Minneapolis, MN) in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry between October 2016 and September 2020 were stratified according to in range (>12%) device oversizing and below range (0%-12%) device oversizing. Patients undergoing valve-in-valve procedures, having a baseline annulus size <26 or ≥34 mm, or without computed tomography angiography measured annulus size were excluded. Percentage of oversizing was calculated as [(valve diameter-annulus diameter)×100/annulus diameter].

resultsTranscatheter aortic valve replacement in patients with large annuli was performed in 8017 patients with a mean (±SD) age 79.3±7.9 years and 94% were male. Below range (n=1096) was less common than in range oversizing (n=6921). At 1-year follow-up, mortality (19.6% versus 14.9%;

conclusionsResults from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry in patients with large annuli valves using 34mm Evolut R/PRO+ valves suggest that in range (>12%) device oversizing delivered better clinical outcomes than implantation with below range (0%-12%) device oversizing.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic ValveFemaleHumansMaleProsthesis DesignRegistriesTreatment Outcomeaortic valve stenosisbioprosthesistranscatheter aortic valve replacement

Identifiers

PMID36943929
PMCPMC10022658

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.