Evidence map›Paper›PMID 36943626›Full record

ArticlePhysical and engineering sciences in medicine2023

Fan beam CT image synthesis from cone beam CT image using nested residual UNet based conditional generative adversarial network.

Jiffy Joseph, Ivan Biji, Naveen Babu, P N Pournami, P B Jayaraj, Niyas Puzhakkal, Christy Sabu, Vedkumar Patel

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Jiffy JosephComputer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India. jiffy_p190037cs@nitc.ac.in.ORCID http://orcid.org/0000-0002-5985-9130
Ivan Biji *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
Naveen Babu *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
P N Pournami *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
P B Jayaraj *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
Niyas Puzhakkal *Department of Medical Physics, MVR Cancer Centre & Research Institute, Poolacode, Calicut, Kerala, 673601, India.
Christy Sabu *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
Vedkumar Patel *Computer science and Engineering Department, National Institute of Technology Calicut, Kattangal, Calicut, Kerala, 673601, India.
National Institute of Technology Calicut · INRegional Cancer Center, Thiruvananthapuram · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A radiotherapy technique called Image-Guided Radiation Therapy adopts frequent imaging throughout a treatment session. Fan Beam Computed Tomography (FBCT) based planning followed by Cone Beam Computed Tomography (CBCT) based radiation delivery drastically improved the treatment accuracy. Furtherance in terms of radiation exposure and cost can be achieved if FBCT could be replaced with CBCT. This paper proposes a Conditional Generative Adversarial Network (CGAN) for CBCT-to-FBCT synthesis. Specifically, a new architecture called Nested Residual UNet (NR-UNet) is introduced as the generator of the CGAN. A composite loss function, which comprises adversarial loss, Mean Squared Error (MSE), and Gradient Difference Loss (GDL), is used with the generator. The CGAN utilises the inter-slice dependency in the input by taking three consecutive CBCT slices to generate an FBCT slice. The model is trained using Head-and-Neck (H&N) FBCT-CBCT images of 53 cancer patients. The synthetic images exhibited a Peak Signal-to-Noise Ratio of 34.04±0.93 dB, Structural Similarity Index Measure of 0.9751±0.001 and a Mean Absolute Error of 14.81±4.70 HU. On average, the proposed model guarantees an improvement in Contrast-to-Noise Ratio four times better than the input CBCT images. The model also minimised the MSE and alleviated blurriness. Compared to the CBCT-based plan, the synthetic image results in a treatment plan closer to the FBCT-based plan. The three-slice to single-slice translation captures the three-dimensional contextual information in the input. Besides, it withstands the computational complexity associated with a three-dimensional image synthesis model. Furthermore, the results demonstrate that the proposed model is superior to the state-of-the-art methods.

Indexed as

Image Processing, Computer-AssistedNeoplasmsCone-Beam Computed TomographyHeadHumansPhantoms, ImagingConditional generative adversarial networkCone beam CTFan beam CTImage synthesis

Identifiers

PMID36943626
OpenAlexW4328049168

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.