Evidence map›Paper›PMID 36943503›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Operating room efficiency after the implementation of MAKO robotic-assisted total knee arthroplasty.

Laura Loomans, Geert Leirs, Hilde Vandenneucker

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Robotic Total Knee Arthroplasty: An Update.Journal of personalized medicine · 2024
    Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Laura LoomansOrthopaedic Surgery, KU Leuven, Herestraat 49, 3000, Leuven, Belgium. laura.loomans@hotmail.com.ORCID http://orcid.org/0000-0002-3494-4224
Geert LeirsOrthopaedic Surgeon, Noorderhart, 3900, Pelt, Belgium.
Hilde VandenneuckerOrthopaedic Surgeon, Department of Orthopaedics, University Hospital Leuven, Department of Development and Regeneration, Institute for Orthopaedic Research and Training (IORT), KU Leuven, 3000, Leuven, Belgium.
KU Leuven · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe aim of this study was to examine if robotic-assisted total knee arthroplasty (RATKA) is cost- and time-effective in terms of implant stock and perioperative parameters, as optimizing perioperative efficiency may contribute to value-based care. MATERIALS AND

methodsFour hundred thirty-two consecutive patients who received primary total knee arthroplasties (TKAs) from May 2017 to March 2020 in a regional hospital were included in this study. Operating room time (OR time), surgical time, number of trays, insert thickness, and length of stay (LOS) were assessed and compared for a cohort group with navigation-assisted procedures to a group with robotic-assisted procedures (MAKO, Stryker, USA). Prediction of implant size was assessed for the robotic-assisted group. The Mann-Whitney U test was used for comparisons between groups when the normality assumption was not met. Categorical variables were assessed using the Fisher's exact test. p < 0.05 was considered statistically significant.

resultsIn the RATKA group, we noticed a significant mean reduction of 11 min in total OR time (p < 0.001), the use of thinner insert (p < 0.001), and a shorter mean length of stay of 1 day (p < 0.001). Compared to the navigation group, surgical time was not significantly longer, nor clinically relevant (0.238). In 76.9% of the robotic-assisted cases, the estimated implant size was equal to the final size and in all other cases, the preoperative implant size was oversized.

conclusionThe introduction of the MAKO robotic-assisted total knee arthroplasty resulted in a gain in operating room time, a thinner and more predictable insert thickness, a shorter length of stay in hospital, and less instrumentation compared to navigation-assisted procedures. Level of evidence Level III, Retrospective cohort study.

Indexed as

Arthroplasty, Replacement, KneeOsteoarthritis, KneeRobotic Surgical ProceduresHumansKnee JointLength of StayOperating RoomsRetrospective StudiesEfficiencyOperating timeRobotic-assisted surgeryTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.