Evidence map›Paper›PMID 36941312›Full record

ArticleScientific reports2023

Safety and effect of pipeline flex embolization device for complex unruptured intracranial aneurysms.

Shun-Qiang Chen, Li Li, Bu-Lang Gao, Qiao-Wei Wu, Qiu-Ji Shao, Zi-Liang Wang, Kun Zhang, Tian-Xiao Li

Open access · goldFull text read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Shun-Qiang Chen *Henan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China. browngao@yeah.net.
Li Li *Henan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Bu-Lang GaoHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Qiao-Wei WuHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Qiu-Ji ShaoHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Zi-Liang WangHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Kun ZhangHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Tian-Xiao LiHenan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, 450000, Henan Province, China.
Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To investigate the safety and short-term effect of Pipeline Flex devices in the treatment of complex unruptured intracranial aneurysms, a retrospective study was performed for patients with complex unruptured intracranial aneurysms who were treated with the Pipeline Flex embolization device (PED Flex device) combined with or without coiling. The clinical, endovascular, and follow-up data were analyzed. One hundred and thirty-one patients with 159 complex unruptured cerebral aneurysms were treated with the PED Flex device, with 144 Flex devices deployed. Periprocedural complications occurred in four patients, resulting in the complication rate of 3.1%, including ischemic complications in three patients (2.3%) and hemorrhagic complication in one (0.8%). At discharge, the mRS was 0 in 101 (77.1%) patients, 1 in 25 (19.1%), 2 in four (3.1%), and 4 in one (0.8%), with the good prognosis rate (mRS 0-2) of 99.2%. Clinical follow-up was carried out in 87 (66.4%) patients 3-42 months after the procedure, with the mRS of 0 in 78 (89.7%), 1 in five (5.7%), 2 in three (3.4%), and 4 in one (1.1%). No significant (P = 0.16) difference existed in the mRS at discharge compared with that at clinical follow-up. Angiographic follow-up was performed in 61 (46.7%) patients with 80 (50.3%) aneurysms at 3-40 months, with the OKM grade of D in 57 (71.3%) aneurysms, C in eight (10%), and B in 15 (18.8%). Asymptomatic instent stenosis occurred in four patients (6.6%). In conclusion: The treatment of complex intracranial aneurysms with the Pipeline Flex embolization device may be safe and effective, with a high complete occlusion rate, a decreased complication rate, and a good prognosis rate at medium follow-up.

Indexed as

Embolization, TherapeuticIntracranial AneurysmCerebral AngiographyFollow-Up StudiesHumansRetrospective StudiesTreatment Outcome

Identifiers

PMID36941312
PMCPMC10027869
OpenAlexW4327946999

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read133
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.