Evidence map›Paper›PMID 36941011›Full record

ArticleBMJ open quality2023

Quality improvement project to reduce unplanned extubations in a paediatric intensive care unit.

Joyce Caroline Dinelli Ferreira, Milena Siciliano Nascimento, Simone Brandi, Cristiane do Prado, Cintia de Cassia Cintra, João Fernando Almeida, Daniel Tavares Malheiro, Antonio Capone

Open access · goldAbstract read
In one paragraph

Article in BMJ open quality, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Joyce Caroline Dinelli FerreiraDepartamento de Qualidade e Segurança, Hospital Israelita Albert Einstein, São Paulo, Brazil.
Milena Siciliano NascimentoDiretoria da Unidade Hospitalar Morumbi e de Práticas Assistenciais, Hospital Israelita Albert Einstein, São Paulo, Brazil milenasn@einstein.br.ORCID 0000-0002-0515-3933
Simone BrandiDiretoria da Unidade Hospitalar Morumbi e de Práticas Assistenciais, Hospital Israelita Albert Einstein, São Paulo, Brazil.
Cristiane do PradoDepartamento Materno-infantil, Hospital Israelita Albert Eisntein, São Paulo, Brazil.
Cintia de Cassia CintraDepartamento Materno-infantil, Hospital Israelita Albert Eisntein, São Paulo, Brazil.
João Fernando AlmeidaDepartamento Materno-infantil, Hospital Israelita Albert Eisntein, São Paulo, Brazil.
Daniel Tavares MalheiroEscritório de Valor, Hospital Israelita Albert Einstein, São Paulo, Brazil.
Antonio CaponeInstitute for Healthcare Improvement, Boston, Massachusetts, USA.
Hospital Israelita Albert Einstein · BRInstitute for Healthcare Improvement · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUnplanned extubations are recurrent adverse events in mechanically ventilated children and have been the focus of quality and safety improvement in paediatric intensive care units (ICUs). LOCAL PROBLEM: To reduce the rate of unplanned extubation in the paediatric ICU by 66% (from 2.02 to 0.7).

methodsThis is a quality improvement project that was conducted in a paediatric ICU of a private hospital at the quaternary level. All hospitalised patients who used invasive mechanical ventilation between October 2018 and August 2019 were included.

interventionsThe project was based on the Improvement Model methodology of the Institute for Healthcare Improvement to implement change strategies. The main ideas of change were innovation in the endotracheal tube fixation model, evaluation of the endotracheal tube positioning, good practices of physical restraint, sedation monitoring, family education and engagement and checklist for prevention of unplanned extubation, with Plan-Do-Study-Act, the tool chosen to test and implement ideas for change.

resultsThe actions reduced the unplanned extubation rate to zero in our institution and sustained this result for a period of 2 years, totalling 743 days without any event. An estimate was made comparing cases with unplanned extubation and controls without the occurrence of this adverse event, which resulted in savings of R$955 096.65 (US$179 540.41) during the 2 years after the implementation of the improvement actions.

conclusionThe improvement project conducted in the 11-month period reduced the unplanned extubation rate to zero in our institution and sustained this result for a period of 743 days. Adherence to the new fixation model and the creation of a new restrictor model, which enabled the implementation of good practices of physical restraint were the ideas of change that had the greatest impact in achieving this result.

Indexed as

Airway ExtubationQuality ImprovementChildHumansIntensive Care Units, PediatricIntubation, IntratrachealRespiration, ArtificialPaediatricsPDSAQuality improvement

Identifiers

PMID36941011
PMCPMC10030672
OpenAlexW4327937602

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.