Evidence map›Paper›PMID 36940986›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2023

[Finite element study of three novel internal fixation modes for bicondylar four-quadrant fractures of tibial plateau].

Chendong Liu, Sunjun Hu, Shimin Chang

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Chendong LiuDepartment of Orthopaedics, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Sunjun HuDepartment of Orthopaedics, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Shimin ChangDepartment of Orthopaedics, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.
Yangpu Hospital of Tongji University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To compare the biomechanical differences among the three novel internal fixation modes in treatment of bicondylar four-quadrant fractures of the tibial plateau through finite-element technique, and find an internal fixation modes which was the most consistent with mechanical principles. Methods: Based on the CT image data of the tibial plateau of a healthy male volunteer, a bicondylar four-quadrant fracture model of the tibial plateau and three experimental internal fixation modes were established by using finite element analysis software. The anterolateral tibial plateaus of groups A, B, and C were fixed with inverted L-shaped anatomic locking plates. In group A, the anteromedial and posteromedial plateaus were longitudinally fixed with reconstruction plates, and the posterolateral plateau was obliquely fixed with reconstruction plate. In groups B and C, the medial proximal tibia was fixed with T-shaped plate, and the posteromedial plateau was longitudinally fixed with the reconstruction plate or posterolateral plateau was obliquely fixed with the reconstruction plate, respectively. An axial load of 1 200 N was applied to the tibial plateau (a simulation of a 60 kg adult walking with physiological gait), and the maximum displacement of fracture and maximum Von-Mises stress of the tibia, implants, and fracture line were calculated in 3 groups. Results: Finite element analysis showed that the stress concentration area of tibia in each group was distributed at the intersection between the fracture line and screw thread, and the stress concentration area of the implant was distributed at the joint of screws and the fracture fragments. When axial load of 1 200 N was applied, the maximum displacement of fracture fragments in the 3 groups was similar, and group A had the largest displacement (0.74 mm) and group B had the smallest displacement (0.65 mm). The maximum Von-Mises stress of implant in group C was the smallest (95.49 MPa), while that in group B was the largest (177.96 MPa). The maximum Von-Mises stress of tibia in group C was the smallest (43.35 MPa), and that in group B was the largest (120.50 MPa). The maximum Von-Mises stress of fracture line in group A was the smallest (42.60 MPa), and that in group B was the largest (120.50 MPa). Conclusion: For the bicondylar four-quadrant fracture of the tibial plateau, a T-shaped plate fixed in medial tibial plateau has a stronger supporting effect than the use of two reconstruction plates fixed in the anteromedial and posteromedial plateaus, which should be served as the main plate. The reconstruction plate, which plays an auxiliary role, is easier to achieve anti-glide effect when it is longitudinally fixed in posteromedial plateau than obliquely fixed in posterolateral plateau, which contributes to the establishment of a more stable biomechanical structure.

Indexed as

TibiaTibial FracturesAdultBiomechanical PhenomenaBone PlatesFinite Element AnalysisFracture Fixation, InternalHumansMalebicondylar four-quadrantfinite element analysisinternal fixationTibial plateau fracture

Identifiers

PMID36940986
PMCPMC10027520
OpenAlexW4328047905

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.