Evidence map›Paper›PMID 36940674›Full record

ArticleAudiology & neuro-otology2023

Event-Related Potentials of Single-Sided Deaf Cochlear Implant Users: Using a Semantic Oddball Paradigm in Noise.

Marcus Voola, Andre Wedekind, An T Nguyen, Welber Marinovic, Gunesh Rajan, Dayse Tavora-Vieira

Open access · hybridAbstract read
In one paragraph

Article in Audiology & neuro-otology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Marcus VoolaDivision of Surgery, Medical School, The University of Western Australia, Perth, Washington, Australia.
Andre WedekindDivision of Surgery, Medical School, The University of Western Australia, Perth, Washington, Australia.
An T NguyenSchool of Population Health, Curtin University, Perth, Washington, Australia.
Welber MarinovicSchool of Population Health, Curtin University, Perth, Washington, Australia.
Gunesh RajanDivision of Surgery, Medical School, The University of Western Australia, Perth, Washington, Australia.
Dayse Tavora-VieiraDivision of Surgery, Medical School, The University of Western Australia, Perth, Washington, Australia.
The University of Western Australia · AUCurtin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn individuals with single-sided deafness (SSD), who are characterised by profound hearing loss in one ear and normal hearing in the contralateral ear, binaural input is no longer present. A cochlear implant (CI) can restore functional hearing in the profoundly deaf ear, with previous literature demonstrating improvements in speech-in-noise intelligibility with the CI. However, we currently have limited understanding of the neural processes involved (e.g., how the brain integrates the electrical signal produced by the CI with the acoustic signal produced by the normal hearing ear) and how modulation of these processes with a CI contributes to improved speech-in-noise intelligibility. Using a semantic oddball paradigm presented in the presence of background noise, this study aims to investigate how the provision of CI impacts speech-in-noise perception of SSD-CI users.

methodTask performance (reaction time, reaction time variability, target accuracy, subjective listening effort) and high density electroencephalography from twelve SSD-CI participants were recorded, while they completed a semantic acoustic oddball task. Reaction time was defined as the time taken for a participant to press the response button after stimulus onset. All participants completed the oddball task in three different free-field conditions with the speech and noise coming from different speakers. The three tasks were: (1) CI-On in background noise, (2) CI-Off in background noise, and (3) CI-On without background noise (Control). Task performance and electroencephalography data (N2N4 and P3b) were recorded for each condition. Speech in noise and sound localisation ability were also measured.

resultsReaction time was significantly different between all tasks with CI-On (M [SE] = 809 [39.9] ms) having faster RTs than CI-Off (M [SE] = 845 [39.9] ms) and Control (M [SE] = 785 [39.9] ms) being the fastest condition. The Control condition exhibited significantly shorter N2N4 and P3b area latency compared to the other two conditions. However, despite these differences noticed in RTs and area latency, we observed similar results between all three conditions for N2N4 and P3b difference area.

conclusionThe inconsistency between the behavioural and neural results suggests that EEG may not be a reliable measure of cognitive effort. This rationale is further supported by different explanations used in past studies to explain N2N4 and P3b effects. Future studies should look to alternative measures of auditory processing (e.g., pupillometry) to gain a deeper understanding of the underlying auditory processes that facilitate speech-in-noise intelligibility.

Indexed as

Cochlear ImplantationCochlear ImplantsSpeech PerceptionEvoked PotentialsHumansSemanticsSpeech IntelligibilityCochlear implantsEvent-related potentialsOddballSingle-sided deafness

Identifiers

PMID36940674
PMCPMC10413801
OpenAlexW4327916305

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.