Evidence map›Paper›PMID 36939909›Full record

ArticleAbdominal radiology (New York)2023

Safety and accuracy of aortic and periaortic CT-guided percutaneous core needle biopsy.

Marika A Pitot, Chris N Gu, Daniel A Adamo, Anil Nicholas Kurup, John J Schmitz, Annie T Packard

Abstract read
PubMed Publisher
In one paragraph

Article in Abdominal radiology (New York), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Marika A PitotDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA. pitot.marika@mayo.edu.ORCID http://orcid.org/0000-0003-0912-0650
Chris N GuDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA.
Daniel A AdamoDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA.
Anil Nicholas KurupDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA.
John J SchmitzDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA.
Annie T PackardDepartment of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to determine the safety and accuracy of aortic and periaortic computed tomography (CT)-guided percutaneous core needle biopsy performed at a single center over 12 years. MATERIALS AND

methodsA retrospective review was conducted of cases performed between February 2010 and August 2022 in which the biopsied region was in direct contact with the aorta or great vessels including the pericardium and common iliac arteries. Clinical notes were reviewed for any early or delayed complications following the procedure, which if present were graded using the National Institute of Health's Common Terminology Criteria for Adverse Events, version 5.0. Pathology results were compared to subsequent outside biopsy results or follow-up surgical pathology, if available, as well as subsequent clinical decision making and/or clinical course, to determine concordance. Sensitivity, specificity, predictive value, and accuracy (indicative of diagnostic yield) were calculated.

results32 core needle biopsies were reviewed from 30 patients (average lesion longest diameter 3.1 cm, range 0.5-10.9 cm; average needle proximity to the vessel endothelium or deep side of the pericardium 1.0 cm, range 0.3-1.8 cm). Complications occurred in 46.9% of cases (15/32), 93.3% (14/15) of which were minor and included small amounts of bleeding or pain. One patient developed a small nonemergent pneumothorax. Of biopsies obtained, 96.9% provided adequate tissue for diagnosis (31/32). When evaluating concordance between pathological and final diagnosis, sensitivity was 94.7% and specificity was 83.3%; positive and negative predictive value were 90.0% and 90.9%, respectively. Accuracy (diagnostic yield) of biopsy was 90.3%.

conclusionCT-guided percutaneous aortic and periaortic core needle biopsies are safe and efficacious procedures with high diagnostic yield.

Indexed as

Image-Guided BiopsyTomography, X-Ray ComputedAortaBiopsy, Large-Core NeedleHumansRetrospective StudiesSensitivity and SpecificityAccuracyAorticCT-guided percutaneous core needle biopsyPeriaorticSafety

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.