ArticleMedical physics2023
Deep learning-based fast volumetric imaging using kV and MV projection images for lung cancer radiotherapy: A feasibility study.
Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- 'See' through the surface: surface-derived three-dimensional AI-driven real-time imaging solution for intra-treatment image guidance.Machine Learning. Health · 2026Article
- Article
- Anatomically informed deep learning framework for generating fast, low-dose synthetic CBCT for prostate radiotherapy.Scientific reports · 2025Article
- Real-time volumetric CBCT reconstruction using surface and X-ray imaging for image-guided radiotherapy.Medical image analysis · 2025Article
- An open-source deep learning framework for respiratory motion monitoring and volumetric imaging during radiation therapy.Medical physics · 2025Article
- CBCT Reconstruction Using Single X-Ray Projection With Cycle-Domain Geometry-Integrated Denoising Diffusion Probabilistic Models.IEEE transactions on medical imaging · 2025Article
- Data-Driven Volumetric Computed Tomography Image Generation From Surface Structures Using a Patient-Specific Deep Leaning Model.International journal of radiation oncology, biology, physics · 2025Article
- Accurate patient alignment without unnecessary imaging using patient-specific 3D CT images synthesized from 2D kV images.Communications medicine · 2024Article
- Patient-Specific CBCT Synthesis for Real-time Tumor Tracking in Surface-guided Radiotherapy.ArXiv · 2024Article
- Artificial intelligence-based motion tracking in cancer radiotherapy: A review.Journal of applied clinical medical physics · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeThe long acquisition time of CBCT discourages repeat verification imaging, therefore increasing treatment uncertainty. In this study, we present a fast volumetric imaging method for lung cancer radiation therapy using an orthogonal 2D kV/MV image pair.
methodsThe proposed model is a combination of 2D and 3D networks. The proposed model consists of five major parts: (1) kV and MV feature extractors are used to extract deep features from the perpendicular kV and MV projections. (2) The feature-matching step is used to re-align the feature maps to their projection angle in a Cartesian coordinate system. By using a residual module, the feature map can focus more on the difference between the estimated and ground truth images. (3) In addition, the feature map is downsized to include more global semantic information for the 3D estimation, which is useful to reduce inhomogeneity. By using convolution-based reweighting, the model is able to further increase the uniformity of image. (4) To reduce the blurry noise of generated 3D volume, the Laplacian latent space loss calculated via the feature map that is extracted via specifically-learned Gaussian kernel is used to supervise the network. (5) Finally, the 3D volume is derived from the trained model. We conducted a proof-of-concept study using 50 patients with lung cancer. An orthogonal kV/MV pair was generated by ray tracing through CT of each phase in a 4D CT scan. Orthogonal kV/MV pairs from nine respiratory phases were used to train this patient-specific model while the kV/MV pair of the remaining phase was held for model testing.
resultsThe results are based on simulation data and phantom results from a real Linac system. The mean absolute error (MAE) values achieved by our method were 57.5 HU and 77.4 HU within body and tumor region-of-interest (ROI), respectively. The mean achieved peak-signal-to-noise ratios (PSNR) were 27.6 dB and 19.2 dB within the body and tumor ROI, respectively. The achieved mean normalized cross correlation (NCC) values were 0.97 and 0.94 within the body and tumor ROI, respectively. A phantom study demonstrated that the proposed method can accurately re-position the phantom after shift. It is also shown that the proposed method using both kV and MV is superior to current method using kV or MV only in image quality.
conclusionThese results demonstrate the feasibility and accuracy of our proposed fast volumetric imaging method from an orthogonal kV/MV pair, which provides a potential solution for daily treatment setup and verification of patients receiving radiation therapy for lung cancer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.