Evidence map›Paper›PMID 36938328›Full record

ArticleFrontiers in allergy2023

Towards standardizing basophil identification by flow cytometry.

Soren Ulrik Sonder, Matthew Plassmeyer, Denise Loizou, Oral Alpan

Open access · goldFull text read
In one paragraph

Article in Frontiers in allergy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 22 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Basophils in atopic dermatitis: Immunologic roles and clinical implications.Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology · 2026
    Review
  7. Review
  8. Review
  9. Article
  10. Towards Personalised Therapy in Chronic Spontaneous Urticaria: Advancing From Endotype to Clinical Response.Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology · 2025
    Review
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Article
  19. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Soren Ulrik SonderAmerimmune, McLean, VA, United States.
Matthew PlassmeyerAmerimmune, McLean, VA, United States.
Denise LoizouAmerimmune, McLean, VA, United States.
Oral AlpanAmerimmune, McLean, VA, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Basophils normally make up <2% of the white blood cells (WBC). There is no clear consensus for basophil identification by flow cytometry. The increased demand for basophil activation test (BAT) to identifying and monitoring allergic patients highlights the need for a standardized approach to identify basophils. Methods: Using flow cytometry we analyzed whole blood stained with antibodies against: IgE, CD123, CD193, CD203c, CD3, HLADR, FcɛRI, CRTH2 and CD45. We examined unstimulated blood as well as blood stimulated with Anti-IgE and fMLP. Finally, we compared the results to a complete blood count (CBC) from an FDA approved hematological analyzer. Results: Basophil identification relying on just one surface marker performed worse than approaches utilizing two identification markers. The percentage of basophils from WBC determined by flow cytometry results had a good correlation with the CBC results even though the CBC results were generally higher. Stimulating whole blood with the basophil activators did not interfere with the basophil identification markers. Conclusion: In flow cytometry assays, two surface markers should be used for identifying basophils and if a very pure basophil fraction is desired a third marker can be considered. In our hands the approaches that included CD123 in combination with either CD193, HLADR

Indexed as

basophil actication testbasophil activating test (BAT)basophil identification markersCBC (complete blood count)flow cytometry

Identifiers

PMID36938328
PMCPMC10020589
OpenAlexW4323044982

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read23
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.