ArticleFrontiers in cardiovascular medicine2023
Building a comprehensive cardiovascular magnetic resonance exam on a commercial 0.55 T system: A pictorial essay on potential applications.
Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.
- Society for Cardiovascular Magnetic Resonance recommendations toward environmentally sustainable cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Guideline
- 3D Simultaneous Post-contrast T1/T2 Mapping and Synthetic Multi-Contrast Late Gadolinium Enhancement at 0.55T: Validation in Porcine Myocardial Infarction Model.Investigative radiology · 2026Article
- Simultaneous 3D structural-functional assessment of pediatric lung using 0.55-T MRI: a feasibility study.Radiology advances · 2026Article
- Leveling the (Playing) Field for Cardiovascular MRI.JACC. Case reports · 2026Article
- Mid-Field Cardiovascular MRI in Class III Obesity.JACC. Case reports · 2026Article
- Cardiac MR Fingerprinting at 0.55T Using a Deep Image Prior for Joint TJournal of magnetic resonance imaging : JMRI · 2026Article
- 4D Flow MRI at 0.6 T-Self-Gating Versus Camera-Based Respiratory Binning.Bioengineering (Basel, Switzerland) · 2026Article
- 3D Whole-Heart Joint TNMR in biomedicine · 2026Article
- Feasibility of Golden Angle Spiral Real-Time Phase Contrast MRI at 0.55T: A Single-Center Prospective Study.Bioengineering (Basel, Switzerland) · 2026Article
- Safety and Engraftment of Aligned Cardiac Patches Loaded with hiPSC-CMs in a Large Animal Model of Myocardial Infarction.Theranostics · 2026Article
- Initial experience of cardiac TMagnetic resonance in medicine · 2025Article
- Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography.Radiology. Cardiothoracic imaging · 2025Article
- Highly efficient image navigator based 3D whole-heart cardiac MRA at 0.55T.Magnetic resonance in medicine · 2025Article
- MRI at low field: A review of software solutions for improving SNR.NMR in biomedicine · 2025Review
- High-resolution 3D whole-heart bright- and black-blood imaging with co-registered T2 mapping at 0.55 T.Frontiers in cardiovascular medicine · 2025Article
- Cardiac Cine MRI Using a Commercially Available 0.55-T Scanner.Radiology. Cardiothoracic imaging · 2024Article
- The impact of severe obesity on image quality and ventricular function assessment in echocardiography and cardiac MRI.The international journal of cardiovascular imaging · 2024Article
- New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal.Magma (New York, N.Y.) · 2024Review
- Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024Review
- Novel Techniques in Imaging Congenital Heart Disease: JACC Scientific Statement.Journal of the American College of Cardiology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 4 institutions in 2 countries.
Funding
Abstract
Background: Contemporary advances in low-field magnetic resonance imaging systems can potentially widen access to cardiovascular magnetic resonance (CMR) imaging. We present our initial experience in building a comprehensive CMR protocol on a commercial 0.55 T system with a gradient performance of 26 mT/m amplitude and 45 T/m/s slew rate. To achieve sufficient image quality, we adapted standard imaging techniques when possible, and implemented compressed-sensing (CS) based techniques when needed in an effort to compensate for the inherently low signal-to-noise ratio at lower field strength. Methods: A prototype CMR exam was built on an 80 cm, ultra-wide bore commercial 0.55 T MR system. Implementation of all components aimed to overcome the inherently lower signal of low-field and the relatively longer echo and repetition times owing to the slower gradients. CS-based breath-held and real-time cine imaging was built utilizing high acceleration rates to meet nominal spatial and temporal resolution recommendations. Similarly, CS 2D phase-contrast cine was implemented for flow. Dark-blood turbo spin echo sequences with deep learning based denoising were implemented for morphology assessment. Magnetization-prepared single-shot myocardial mapping techniques incorporated additional source images. CS-based dynamic contrast-enhanced imaging was implemented for myocardial perfusion and 3D MR angiography. Non-contrast 3D MR angiography was built with electrocardiogram-triggered, navigator-gated magnetization-prepared methods. Late gadolinium enhanced (LGE) tissue characterization methods included breath-held segmented and free-breathing single-shot imaging with motion correction and averaging using an increased number of source images. Proof-of-concept was demonstrated through porcine infarct model, healthy volunteer, and patient scans. Results: Reasonable image quality was demonstrated for cardiovascular structure, function, flow, and LGE assessment. Low-field afforded utilization of higher flip angles for cine and MR angiography. CS-based techniques were able to overcome gradient speed limitations and meet spatial and temporal resolution recommendations with imaging times comparable to higher performance scanners. Tissue mapping and perfusion imaging require further development. Conclusion: We implemented cardiac applications demonstrating the potential for comprehensive CMR on a novel commercial 0.55 T system. Further development and validation studies are needed before this technology can be applied clinically.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.