Evidence map›Paper›PMID 36937173›Full record

ArticleAnesthesiology and pain medicine2022

Role of Lung Ultrasound in Confirmation of Double Lumen Endotracheal Tube Placement for Thoracic Surgeries: A Prospective Diagnostic Accuracy Study.

Walaa Y Elsabeeny, Mostafa A Ibrahim, Sayed M Abed, Nahla N Shehab

Open access · diamondAbstract read
In one paragraph

Article in Anesthesiology and pain medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Walaa Y ElsabeenyDepartment of Anesthesia, Intensive Care and Pain Management, National Cancer Institute, Cairo University, Cairo, Egypt.ORCID https://orcid.org/0000-0003-3047-6926
Mostafa A IbrahimDepartment of Anesthesia, Intensive Care and Pain Management, National Cancer Institute, Cairo University, Cairo, Egypt.ORCID https://orcid.org/0000-0001-5131-0971
Sayed M AbedDepartment of Anesthesia, Intensive Care and Pain Management, National Cancer Institute, Cairo University, Cairo, Egypt.ORCID https://orcid.org/0000-0003-2362-5508
Nahla N ShehabDepartment of Anesthesia, Intensive Care and Pain Management, National Cancer Institute, Cairo University, Cairo, Egypt.ORCID https://orcid.org/0000-0003-3211-5147
Cairo University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In thoracic surgeries requiring thoracotomy incisions, correct positioning of the double-lumen endotracheal tube (DLT) is mandatory. After the pandemic of novel COVID-19, using simple, noninvasive technology such as lung ultrasound (LUS) can be important in avoiding the possibility of spreading infectious diseases or contagious infections that can follow using fiberoptic bronchoscopy (FOB). Objectives: We aimed to assess the accuracy of auscultation and LUS in relation to FOB in the assessment of DLT placement and to identify the possibility of using LUS as an alternative to FOB during DLT insertion. Methods: This diagnostic accuracy study was conducted according to STARD guidelines; enrolled 120 cases requiring DLT intubation. After DLT insertion, all patients were examined by stethoscope, then by LUS for determination of DLT position, and then confirmed by FOB in the same patient. Results: Three patients dropped out due to failed intubation, and only 117 cases were analyzed. Time was significantly longer for LUS than for auscultation and FOB and was insignificantly different between auscultation and FOB. Auscultation had 76.14% sensitivity, 34.48% specificity, and 65.81% accuracy in the determination of correct DLT placement. LUS had 92.05% sensitivity, 79.31% specificity, and 88.89% accuracy in detecting correct DLT placement. There was substantial agreement between LUS and FOB (κ = 0.705) and poor agreement between auscultation and FOB (κ = 0.104). Conclusions: LUS can be used as a simple, noninvasive tool for detecting DLT placement with a substantial agreement with FOB.

Indexed as

AuscultationBronchoscopyIntubationUltrasound

Identifiers

PMID36937173
PMCPMC10016132
OpenAlexW4309780574

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.