ArticleAsiaIntervention2023
Predictors of bioprosthetic valve dysfunction after transcatheter aortic valve implantation.
Article in AsiaIntervention, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Long-term impact of prosthesis-patient mismatch after transcatheter aortic valve replacement.Cardiovascular intervention and therapeutics · 2026Article
- Evidence of bioprosthetic valve dysfunction during three-year follow-up following TAVR.Clinical research in cardiology : official journal of the German Cardiac Society · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Recently, the Valve Academic Research Consortium (VARC)-3 criteria redefined bioprosthetic valve dysfunction (BVD) after transcatheter aortic valve implantation (TAVI). However, the rate of BVD is scarcely reported in current practice. Aims: We aimed to evaluate the rate and predictors of BVD after TAVI based on the VARC-3 criteria. Methods: We retrospectively analysed patients who had undergone TAVI using single-centre data. BVD was reported as exposure-adjusted event rates with a patient-year unit (per 100 patient-years). Predictors of BVD after TAVI were analysed using Fine-Gray competing risk regression to account for the competing risk of death. Results: Among 514 patients, the rate of BVD was 7.5 events per 100 patient-years (n=74) at a median follow-up of 1.9 years. The main cause of BVD was moderate or severe prosthesis-patient mismatch (PPM; n=59). The Fine-Gray model demonstrated that predilatation was associated with a lower rate of BVD, mainly moderate or severe PPM (adjusted subdistribution hazard ratio [sub-HR] 0.42, 95% confidence interval [CI]: 0.21-0.88). In a subgroup analysis, the patients with a small aortic annulus (area <400 mm Conclusions: Our study suggested that the rate of BVD in patients undergoing TAVI is relatively low at midterm follow-up. Predilatation, particularly in small annuli and small BEV might have an impact on BVD, mainly caused by moderate or severe PPM, after TAVI.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.