Evidence map›Paper›PMID 36935488›Full record

ArticleJournal of orthopaedic surgery and research2023

Spinal alignment measurement with Kinect sensor is valid for thoracic kyphosis but not for lumbar lordosis.

Hitoshi Koda, Yoshihiro Kai, Noriyuki Kida, Toru Morihara

Open access · goldFull text read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Hitoshi KodaDepartment of Rehabilitation Sciences, Faculty of Allied Health Sciences, Kansai University of Welfare Sciences, 3-11-1, Asahigaoka, Kashiwara-City, Osaka, 582-0026, Japan. h-koda@tamateyama.ac.jp.
Yoshihiro KaiDepartment of Physical Therapy, Faculty of Health Science, Kyoto Tachibana University, Kyoto, Japan.
Noriyuki KidaFaculty of Arts and Sciences, Kyoto Institute of Technology University, Kyoto, Japan.
Toru MoriharaDepartment of Orthopedics, Marutamachi Rehabilitation Clinic, Kyoto, Japan.
Kansai University of Welfare Sciences · JPKyoto Institute of Technology · JPKyoto Tachibana University · JP

Funding

Japan Society for the Promotion of Science 22K17544
6 · The paper itself

Abstract

backgroundSpinal alignment evaluation is commonly performed in the clinical setting during rehabilitation. However, there is no simple method for its quantitative measurement. Recently, the depth cameras in Kinect sensors have been employed in various commercial and research projects in the healthcare field. We hypothesized that the time-of-flight technology of the Kinect sensor could be applied to quantitatively evaluate spinal alignment. The purpose of this study was to develop a simple and noninvasive evaluation for spinal alignment using the Kinect sensor and to investigate its validity.

methodsTwenty-four healthy men participated in the study. Measurement outcomes were the thoracic kyphosis and lumbar lordosis angles in the standing position, using a Spinal Mouse, the validity of which has been previously reported, and the Kinect sensor. In the measurement by the Kinect sensor, a program was created to obtain the three-dimensional coordinates of each point within an area marked on the monitor, and the sums of the angles at each vertebral level were calculated for the thoracic and lumbar areas. Pearson's correlation coefficient was used to analyze the relationship between the Kinect sensor and Spinal Mouse measurements of thoracic kyphosis and lumbar lordosis angles.

resultsThere was a significant positive and moderate correlation between the thoracic kyphosis measurements taken by each device. Contrarily, there was no significant correlation in the lordosis angle between measurements using the Kinect sensor and Spinal Mouse.

conclusionsOur results demonstrated the validity of measuring the thoracic kyphosis angle using the Kinect sensor. This indicates that the depth camera in the Kinect sensor is able to perform accurate thoracic alignment measurements quickly and noninvasively.

Indexed as

KyphosisLordosisAnimalsLumbar VertebraeMiceSpineThoracic VertebraeAssessmentKinect sensorSpinal alignment

Identifiers

PMID36935488
PMCPMC10024834
OpenAlexW4327900258

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read3
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.