Evidence map›Paper›PMID 36935361›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants.

Christian Böhler, Maria Vomero, Marisol Soula, Mihály Vöröslakos, Maria Porto Cruz, Rickard Liljemalm, György Buzsaki, Thomas Stieglitz, Maria Asplund

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Friend, Not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  5. Article
  6. Article
  7. PEDOT:PSS-A Key Material for Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  8. Article
  9. Article
  10. Capturing the Electrical Activity of all Cortical Neurons: Are Solutions Within Reach?Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Review
  18. Review
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Christian BöhlerDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.ORCID 0000-0002-7961-7411
Maria VomeroDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.ORCID 0000-0002-3721-0904
Marisol SoulaNeuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA.
Mihály VöröslakosNeuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA.
Maria Porto CruzDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.
Rickard LiljemalmDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.
György BuzsakiNeuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA.
Thomas StieglitzDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.ORCID 0000-0002-7349-4254
Maria AsplundDepartment of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany.ORCID 0000-0001-8779-7478

Funding

European Research Council StG759655SPEEDERNIH HHS NIH U19 NS107616
6 · The paper itself

Abstract

Flexible implantable neurointerfaces show great promise in addressing one of the major challenges of implantable neurotechnology, namely the loss of signal connected to unfavorable probe tissue interaction. The authors here show how multilayer polyimide probes allow high-density intracortical recordings to be combined with a reliable long-term stable tissue interface, thereby progressing toward chronic stability of implantable neurotechnology. The probes could record 10-60 single units over 5 months with a consistent peak-to-peak voltage at dimensions that ensure robust handling and insulation longevity. Probes that remain in intimate contact with the signaling tissue over months to years are a game changer for neuroscience and, importantly, open up for broader clinical translation of systems relying on neurotechnology to interface the human brain.

Indexed as

BrainElectrodes, ImplantedHumansbioelectronicschronic recordingsconducting polymersflexible probesneurotechnologytissue-device interfaces

Identifiers

PMID36935361
PMCPMC10190290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.