Evidence map›Paper›PMID 36932215›Full record

ArticleEuropean radiology2023

Optimized radiological alert thresholds based on device-dosimetric information to predict peak skin dose between 2 and 4 Gy during vascular fluoroscopically guided intervention.

Nicolas Sas, Jean-Baptiste Lacroix, Véronique Dedieu, Louis Boyer

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nicolas SasDepartment of Medical Physics, Jean Perrin Comprehensive Cancer Center, 63000, Clermont-Ferrand, France. nicolas.sas@clermont.unicancer.fr.ORCID http://orcid.org/0000-0002-5398-6382
Jean-Baptiste LacroixDepartment of Medical Physics, Jean Perrin Comprehensive Cancer Center, 63000, Clermont-Ferrand, France.
Véronique DedieuDepartment of Medical Physics, Jean Perrin Comprehensive Cancer Center, 63000, Clermont-Ferrand, France.
Louis BoyerPôle Interhospitalier d'Imagerie Diagnostique Et de Radiologie Interventionnelle, CHU, 63003, Clermont-Ferrand, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo provide radiologists and physicists with methodological tools to improve patient management after vascular fluoroscopically guided intervention (FGI) by providing optimized thresholds (OT) values that could be used as a surrogate to the thresholds classically proposed by the National Council on Radiation Protection (NCRP) or could be useful to adapt their own substantial radiation dose levels (SRDL) values.

methodsPSD of 2000-4000 mGy after FGI were calculated for 258 patients with dedicated software. Overall, the kerma and KAP 3D-ROC curves were used to assess the sensitivity (SEN) and specificity (SPE) of NCRP thresholds and OT for each PSD. Kiviat diagram and density curves were plotted for the best SEN/SPE pair of 3D-ROC curves and compared to the NCRP thresholds.

resultsOT for both kerma and KAP generating the best SEN/SPE couple for PSD of 2000-4000 mGy were obtained. The SEN/SPE couple of each OT was always better than that obtained using NCRP ones. The best OT among all those calculated providing the highest SEN/SPE values for kerma (3020.5 mGy) and KAP (741.02 Gy.cm

conclusionsWe have calculated OT in terms of kerma and KAP based on 3D-ROC curves analysis and peak skin dose calculations that can be obtained to better predict high skin dose. The use of OT that predicted PSD greater than 3000 mGy is likely to improve patient follow-up. The methodology developed in this work could be adapted to other institutions in order to better define their own SRDL. KEY POINTS: • Optimized dose thresholds in terms of kerma and KAP based on 3D-ROC curves analysis and peak skin dose calculations between 2000 and 4000 mGy can be obtained to better predict high skin dose. • Patients receiving a peak skin dose between 2000 and 4000 mGy have their follow-up enhanced by using the optimized thresholds instead of the NCRP thresholds. • The best-optimized thresholds, corresponding to 3020.5 mGy and 741.02 Gy.cm

Indexed as

FluoroscopyRadiology, InterventionalSkinAdultAgedHumansMiddle AgedRadiation DosageRadiometryROC CurveInterventional radiologyPatient follow-upRadiation dosimetryROC curveSoftware

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.