Abdominal MR elastography with multiple driver arrays: performance and repeatability.

Jie Chen, Jun Chen, Jeremiah A Heilman, Kevin J Glaser, Roger C Grimm, Nana Owusu, Caixin Qiu, Richard L Ehman, Meng Yin

Open access · greenAbstract read
In one paragraph

Article in Abdominal radiology (New York), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Imaging Evaluation for Steatotic Liver Disease.Korean journal of radiology · 2026
    Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. MR Elastography: Practical Questions, From theAJR. American journal of roentgenology · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Jie ChenDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.ORCID http://orcid.org/0000-0001-7446-7541
Jun ChenDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Jeremiah A HeilmanDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Kevin J GlaserDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Roger C GrimmDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Nana OwusuDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Caixin QiuDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Richard L EhmanDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Meng YinDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. yin.meng@mayo.edu.ORCID http://orcid.org/0000-0001-6778-192X
Mayo Clinic · US

Funding

Comprehensive noninvasive assessment of liver histopathology in nonalcoholic fatty liver disease (NAFLD) via magnetic resonance imaging, cytometry and elastography (MR-ICE)R01EB017197 · NIBIB · MAYO CLINIC ROCHESTER · PI YIN, MENG · 2014 to 2025
$4.3M
Magnetic Resonance ElastographyR37EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2016 to 2025
$4.0M
NIBIB NIH HHS R01 EB017197NIBIB NIH HHS R37 EB001981
6 · The paper itself

Abstract

purposeTo evaluate the performance and repeatability assessing liver, spleen, and kidney stiffness with magnetic resonance elastography (MRE), using arrays of pneumatic passive drivers.

methodsAn array of four flexible, pneumatically activated passive drivers for abdominal MRE were developed and tested in this study. Multiple MRE acquisitions were performed prospectively in a series of eleven volunteers, with activation of all combinations of the four drivers, individually and simultaneously. MRE exams were repeated three times to study within-day and between-day test-retest repeatability. Semi-quantitative evaluation of wave propagation and penetration, and quantitative assessment of tissue stiffness was conducted for liver, spleen, and kidneys.

resultsWhen driver location and amplitude were sufficient to achieve necessary shear wave illumination in any given region of interest, the results showed excellent test-retest repeatability in abdominal organ stiffness with both single and multiple driver configurations. The results confirmed that multiple driver arrays provided suitable shear wave illumination over a larger region of the abdomen, allowing more reliable stiffness measurements in multiple organs. MRE assessment of the spleen was found to be prone to effects of excessive shear wave amplitude, however.

conclusionA multiple driver array provides shear wave illumination over a larger region of the abdomen than obtained with a single driver, for MRE assessment of multiple abdominal organs, providing excellent test-retest repeatability in stiffness measurements. However, careful tuning of the location and amplitude of each driver is essential to achieve consistent results.

Indexed as

Elasticity Imaging TechniquesAbdomenHumansKidneyLiverMagnetic Resonance ImagingReproducibility of ResultsSpleenLiver stiffnessMagnetic resonance elastographyMultiple driver arraysRenal stiffnessRepeatabilitySpleen stiffness

Identifiers

PMID36928333
PMCPMC10201649
OpenAlexW4327682128

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.