Evidence map›Paper›PMID 36925522›Full record

ArticleHeliyon2023

Research on the cross-contamination in the confined conference room with the radiant floor heating system integrated with the down-supply ventilation.

Jie Wu, Liang Xu, JingHua Shen

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jie WuSchool of Architecture, Soochow University, Suzhou, China.
Liang XuSchool of Architecture, Soochow University, Suzhou, China.
JingHua ShenSchool of Architecture, Soochow University, Suzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The performance of a confined conference room under radiant heat floor combined with down-supply ventilation (RFDS) is investigated. The purpose of the study is to reveal the mechanism of indoor contaminants transmission from infected person and to protect the occupants. The exhaled contaminant dispersion was simulated using a CFD model and experimentally validated in an office with the down-supply ventilation (DS). The effects of radiant floor (RF) combined with down-supply ventilation on airflow and contaminant distribution in the room was evaluated with regard to different RF temperatures and inlet velocities. The influence of downdraft from the envelope on the airflow pattern of the room is also discussed. It is proved that the exposure risk of pollutants can be reduced by strengthening the insulation of the envelope. The simulation results showed that the proposed RFDS system could significantly reduce the level of exposure to contaminants in the breathing zone (BZ) of occupants. In this research case, the RFDS reduced the average exposure rates by more than 50% relative to the case with the only down-supply warm air heating. Furthermore, With improved envelope insulation, the probability of infection can be reduced by more than 80% only by avoiding a simultaneous inlet velocity of 0.3 m/s at RF temperatures no less than 27 °C. The results suggested an improved fresh air heating mode for passive ultra-low energy consumption buildings with good thermal insulation and air tightness.

Indexed as

Cross-contaminationDown-supply ventilationEnvelope insulationRadiant floor system

Identifiers

PMID36925522
PMCPMC10010993

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.