Comparison of MR-soft tissue based versus biliary stent based alignment for image guidance in pancreatic SBRT.
Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparison of MR-soft tissue based versus biliary stent based alignment for image guidance in pancreatic SBRT.Journal of applied clinical medical physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe role of biliary stents in image-guided localization for pancreatic cancer has been inconclusive. To date, stent accuracy has been largely evaluated against implanted fiducials on cone beam computed tomography. We aim to use magnetic resonance (MR) soft tissue as a direct reference to examine the geometric and dosimetric impacts of stent-based localization on the newly available MR linear accelerator.
methodsThirty pancreatic cancer patients (132 fractions) treated on our MR linear accelerator were identified to have a biliary stent. In our standard adaptive workflow, patients were set up to the target using soft tissue for image registration and structures were re-contoured on daily MR images. The original plan was then projected on treatment anatomy and dose predicted, followed by plan re-optimization and treatment delivery. These online predicted plans were soft tissue-based and served as reference plans. Retrospective image registration to the stent was performed offline to simulate stent-based localization and the magnitude of shifts was taken as the geometric accuracy of stent localization. New predicted plans were generated based on stent-alignment for dosimetric comparison.
resultsShifts were within 3 mm for 90% of the cases (mean = 1.5 mm); however, larger shifts up to 7.2 mm were observed. Average PTV coverage dropped by 1.1% with a maximum drop of 26.8%. The mean increase in V35Gy was 0.15, 0.05, 0.02, and 0.02 cc for duodenum, stomach, small bowel and large bowel, respectively. Stent alignment was significantly worse for all metrics except for small bowel (p = 0.07).
conclusionsOverall discrepancy between stent- and soft tissue-alignment was modest; however, large discrepancies were observed for select cases. While PTV coverage loss may be compensated for by using a larger margin, the increase in dose to gastrointestinal organs at risk may limit the role of biliary stents in image-guided localization.