In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Keiichiro MinamiDepartment of Ophthalmology, Tokyo Dental College Suidobashi Hospital, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan. minamik@tdc.ac.jp.
Saori YaguchiDepartment of Ophthalmology, Tokyo Dental College Suidobashi Hospital, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Hiroko Bissen-MiyajimaDepartment of Ophthalmology, Tokyo Dental College Suidobashi Hospital, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Tokyo Dental College · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

During cataract surgery, the intraocular temperature changes when irrigating low-temperature fluid and ophthalmic viscosurgical devices (OVDs) are inserted in the anterior chamber, and such a temperature variation affects the unfolding of the intraocular lens (IOL). A porcine eye holder was developed for simulating temperature conditions in clinical surgery by maintaining the ocular temperature close to the body temperature. An aluminum holder was designed to fit porcine eyes and maintain the ocular temperature at approximately 36 °C, while surgery was performed at a room temperature of 20 °C. Intraocular temperature was monitored using a thermocouple sensor placed close to the posterior capsule in the vitreous cavity. Temperatures and microscopic image of the anterior chamber were simultaneously recorded. With the use of the eye holder system, the intraocular temperature unstable during surgery was observed, and there were significant reductions during hydrodissection, irrigation and aspiration, OVD insertion in the capsule, and OVD removal after IOL implantation.

Indexed as

CataractCataract ExtractionPhacoemulsificationAnimalsLens Implantation, IntraocularSwineTemperature

Identifiers

PMID36922583
PMCPMC10017689
OpenAlexW4324386987

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read53
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.