ArticleCardiovascular and interventional radiology2023
Coil Embolization of True, Common and Proper, Hepatic Artery Aneurysms: Technique, Safety and Outcome.
Article in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Endovascular repair with covered stent for a giant hepatic artery pseudoaneurysm: a case report and literature review.Frontiers in medicine · 2025Article
- Article
- Clinical application of medical adhesive in endovascular embolization treatment of peripheral pseudoaneurysm.Journal of clinical imaging science · 2024Article
- Intrahepatic aneurysm in a branch of the right hepatic artery in a patient with vasculitis due to systemic lupus erythematosus.Przeglad gastroenterologiczny · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo retrospectively assess the safety and efficacy of coil embolization for catheter-directed true common and proper hepatic artery aneurysm exclusion. MATERIALS AND
methodsNine consecutive patients (2005-2021) in two university centers presenting with true common and proper hepatic artery aneurysms (> 2 cm in diameter) were treated with 'frontdoor-backdoor' coil embolization. Patients presenting with a hepatic artery pseudoaneurysm, mycotic aneurysm or patients with small (< 2 cm diameter) aneurysms and followed up by imaging were excluded. Technical and clinical success was defined as complete coil-exclusion of the aneurysm on completion angiography and absence of post-embolization adverse events, in particular mass effect or hemorrhage, respectively. Patient characteristics, technical and clinical success, liver function tests and follow-up results were assessed based on the patients' electronic medical records.
resultsTechnical and 30-day clinical success was achieved in all procedures (100%). No major procedural complications were reported. Liver function test values were available in 6/9 patients, showing transient elevation of bilirubin in one patient. No end organ ischemia was reported. The mean clinical follow-up period of the study patients was 72 months (12-168 months). Long-term stable occlusion of the hepatic aneurysms was achieved in 9/9 patients (100%). One patient showed late complication (3 years) with coil migration into a bulbar ulcer, without aneurysm recanalization, however with fatal outcome.
conclusionCoil embolization for the endovascular exclusion of true common and proper hepatic artery aneurysms is safe and effective.