Evidence map›Paper›PMID 36917322›Full record

ArticleJournal of experimental orthopaedics2023

Impacted bone allograft personalised by a novel 3D printed customization kit produces high surgical accuracy in medial opening wedge high tibial osteotomy: a pilot study.

Wouter Van Genechten, Annemieke Van Haver, Stijn Bartholomeeusen, Toon Claes, Nathalie Van Beek, Jozef Michielsen, Steven Claes, Peter Verdonk

Full text read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wouter Van GenechtenOrthopedic Department, University Hospital Antwerp, Antwerp, Belgium. Wouter.vangenechten22@gmail.com.ORCID http://orcid.org/0000-0001-5844-9247
Annemieke Van HaverMore Institute, Antwerp, Belgium.
Stijn BartholomeeusenOrthopedic Department, AZ Herentals, Herentals, Belgium.
Toon ClaesOrthopedic Department, AZ Herentals, Herentals, Belgium.
Nathalie Van BeekOrthopedic Department, AZ Herentals, Herentals, Belgium.
Jozef MichielsenOrthopedic Department, University Hospital Antwerp, Antwerp, Belgium.
Steven ClaesMore Institute, Antwerp, Belgium.
Peter VerdonkOrthopedic Department, University Hospital Antwerp, Antwerp, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeContemporary medial opening wedge high tibial osteotomy (MOWHTO) still seems to struggle with inconsistent accuracy outcomes. Our objective was to assess surgical accuracy and short-term clinical outcomes when using 3D planning and a patient-specific instrumentation (PSI) kit to prepare customized bone allografts.

methodsThirty subjects (age 48y ± 13) were included in a double-center prospective case series. A low-dose CT-scan was performed to generate 3D bone models, a MOWHTO was simulated, and PSI was designed and 3D printed based on the complementary negative of the planned osteotomy gap. Clinical outcome was assessed at two, four, 12 weeks and one year using NRS, KOOS, UCLA activity score, EQ-5D and anchor questions. A linear-mixed model approach was implemented for data analysis.

resultsPreoperative 3D values were 175.0° ± 2.2 mechanical tibiofemoral angle (mTFA), 85.0° ± 3.0 medial proximal tibial angle (MPTA), and 94.1° ± 3.4 medial posterior tibial slope (MPTS). Target planning ranged from slight varus to the lateral tibial spine (slight valgus). Postoperative 3D analysis showed an accuracy of 1.1° ± 0.7 ΔMPTA (p = 0.04) and 1.2° ± 1.2 ΔMPTS (p = 0.11). NRS decreased from baseline 6.1 ± 1.9 to 2.7 ± 1.9 at four weeks (p < 0.001) and 1.7 ± 1.9 at one year (p < 0.001). KOOS increased from 31.4 ± 17.6 to 50.6 ± 20.6 at 12 weeks (p < 0.001) and to 71.8 ± 15.6 at one year (p < 0.001).

conclusionThe study suggests that 3D printed instrumentation to personalize structural bone allograft is a viable alternative method in MOWHTO that has the benefit of optimizing surgical accuracy while providing early and consistent pain relief after surgery.

Indexed as

3D planningAccuracyHigh tibial osteotomyJoint preservationPatient-specific instrumentation

Identifiers

PMID36917322
PMCPMC10012299

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read44
table measurements read22
Read underepoch 390

Registered trials

None linked