Evidence map›Paper›PMID 36915565›Full record

ArticleHeliyon2023

Investigation on the basic principles of human-machine contact force, based on screw theory.

Xin Zhou, Zhisheng Duan

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Xin ZhouCenter for Systems and Control, Department of Mechanics and Engineering Science, Peking University, Beijing, 100871, China.
Zhisheng DuanCenter for Systems and Control, Department of Mechanics and Engineering Science, Peking University, Beijing, 100871, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, to introduce a spatial rigid body mechanics analytical method and start the analysis, the human-machine contact force is equivalent to a spatially rigid body: the mechanism and skin surfaces are equivalent to two different rigid planes, and the motion between the mechanism and skin surfaces is equivalent to virtual branches motion. By considering the elastic deformation of each virtual branch axis, an equivalent human-machine contact force model is established, along with the deformation coordination equation of each virtual branch. The analytical solution of the tension/compression and the expression of the internal force of each virtual branch are obtained by solving the pseudo inverse and weighted generalized inverse solutions of the human-machine contact force. The physical meaning of the internal force of each virtual branch is also denoted. In addition, this paper contains an experimental platform for testing human-machine contact force, in which the linear stiffness of each branch is evaluated, therefore simulating and verifying the theoretical model introduced above. The contact force model proposed in this paper provides a theoretical basis for the development of human-machine synergetic motion.

Indexed as

Compatibility of deformationHuman-machine contact forceInternal forceLinear stiffnessParallel mechanism

Identifiers

PMID36915565
PMCPMC10006436

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.