Using pressure-driven flow systems to evaluate laser speckle contrast imaging.

Colin T Sullender, Adam Santorelli, Lisa M Richards, Pawan K Mannava, Christopher Smith, Andrew K Dunn

Full text read
In one paragraph

Article in Journal of biomedical optics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Mapping fast tissue dynamics with long camera exposures via intensity modulation.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  3. Article
  4. Article
  5. Wide-field intensity fluctuation imaging.Biomedical optics express · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Colin T SullenderThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.ORCID 0000-0003-4329-7708
Adam SantorelliThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.ORCID 0000-0002-8951-4619
Lisa M RichardsThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.ORCID 0000-0003-0656-3800
Pawan K MannavaThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.
Christopher SmithThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.
Andrew K DunnThe University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States.ORCID 0000-0001-6500-5783

Funding

Optical Imaging of Baseline Blood Flow and Oxygenation During StrokeR01EB011556 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI DUNN, ANDREW K · 2010 to 2018
$3.1M
Longitudinal Imaging of Cortical Small Vessel Network Structure with Two-Color Multiphoton Fluorescence MicroscopyR01NS108484 · NINDS · UNIVERSITY OF TEXAS AT AUSTIN · PI DUNN, ANDREW K · 2018 to 2022
$2.8M
Comprehensive Training Program in Imaging Science and InformaticsT32EB007507 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI MARKEY, MIA K, RYLANDER, HENRY GRADY · 2009 to 2024
$2.7M
NIBIB NIH HHS R01 EB011556NIBIB NIH HHS T32 EB007507NINDS NIH HHS R01 NS108484
6 · The paper itself

Abstract

Significance: Microfluidic flow phantom studies are commonly used for characterizing the performance of laser speckle contrast imaging (LSCI) instruments. The selection of the flow control system is critical for the reliable generation of flow during testing. The majority of recent LSCI studies using microfluidics used syringe pumps for flow control. Aim: We quantified the uncertainty in flow generation for a syringe pump and a pressure-regulated flow system. We then assessed the performance of both LSCI and multi-exposure speckle imaging (MESI) using the pressure-regulated flow system across a range of flow speeds. Approach: The syringe pump and pressure-regulated flow systems were evaluated during stepped flow profile experiments in a microfluidic device using an inline flow sensor. The uncertainty associated with each flow system was calculated and used to determine the reliability for instrument testing. The pressure-regulated flow system was then used to characterize the relative performance of LSCI and MESI during stepped flow profile experiments while using the inline flow sensor as reference. Results: The pressure-regulated flow system produced much more stable and reproducible flow outputs compared to the syringe pump. The expanded uncertainty for the syringe pump was 8 to Conclusions: Pressure-regulated flow systems should be used instead of syringe pumps when assessing the performance of flow measurement techniques with microfluidic studies. MESI offers more accurate relative flow measurements than traditional LSCI across a wide range of flow speeds.

Indexed as

Diagnostic ImagingLaser Speckle Contrast ImagingLaser-Doppler FlowmetryPhantoms, ImagingRegional Blood FlowReproducibility of Resultsdynamic light scatteringflow measurementflow systemlaser speckle contrast imagingmicrofluidicmulti-exposure speckle imaging

Identifiers

PMID36915371
PMCPMC10007838

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read30
table measurements read3
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.