Evidence map›Paper›PMID 36915339›Full record

ArticleQuantitative imaging in medicine and surgery2023

Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study.

Yunsub Jung, Jin Hur, Kyunghwa Han, Yasuhiro Imai, Yoo Jin Hong, Dong Jin Im, Kye Ho Lee, Melissa Desnoyers, Brian Thomsen, Risa Shigemasa and 2 more

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Shedding light on the management of acute radiation dermatitis: insight from the MASCC Oncodermatology study group.Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Yunsub JungResearch Team, GE Healthcare Korea, Seoul, Republic of Korea.
Jin HurDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Kyunghwa HanDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Yasuhiro ImaiCT System Group, GE Healthcare Japan, Hino, Japan.
Yoo Jin HongDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Dong Jin ImDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Kye Ho LeeDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Melissa DesnoyersGlobal Research Team, GE Healthcare US, Milwaukee, WI, USA.
Brian ThomsenGlobal Research Team, GE Healthcare US, Milwaukee, WI, USA.
Risa ShigemasaGlobal Research Team, GE Healthcare US, Milwaukee, WI, USA.
Kyounga UmResearch Team, GE Healthcare Korea, Seoul, Republic of Korea.
Kyungeun JangResearch Team, GE Healthcare Korea, Seoul, Republic of Korea.
GE Global Research (United States) · USYonsei University · KRSeverance Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The aim of this study was to compare the dose reduction potential and image quality of deep learning-based image reconstruction (DLIR) with those of filtered back-projection (FBP) and iterative reconstruction (IR) and to determine the clinically usable dose of DLIR for low-dose chest computed tomography (LDCT) scans. Methods: Multi-slice computed tomography (CT) scans of a chest phantom were performed with various tube voltages and tube currents, and the images were reconstructed using seven methods to control the amount of noise reduction: FBP, three stages of IR, and three stages of DLIR. For subjective image analysis, four radiologists compared 48 image data sets with reference images and rated on a 5-point scale. For quantitative image analysis, the signal to noise ratio (SNR), contrast to noise ratio (CNR), nodule volume, and nodule diameter were measured. Results: In the subjective analysis, DLIR-Low (0.46 mGy), DLIR-Medium (0.31 mGy), and DLIR-High (0.18 mGy) images showed similar quality to the FBP (2.47 mGy) image. Under the same dose conditions, the SNR and CNR were higher with DLIR-High than with FBP and all the IR methods (all P<0.05). The nodule volume and size with DLIR-High were significantly closer to the real volume than with FBP and all the IR methods (all P<0.001). Conclusions: DLIR can improve the image quality of LDCT compared to FBP and IR. In addition, the appropriate effective dose for LDCT would be 0.24 mGy with DLIR-High.

Indexed as

chest phantomdeep learning-based image reconstruction (DLIR)Low-dose chest computed tomography (LDCT)

Identifiers

PMID36915339
PMCPMC10006148
OpenAlexW4319987397

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.