ArticleQuantitative imaging in medicine and surgery2023
Dark blood T2-weighted imaging of the human heart with AI-assisted compressed sensing: a patient cohort study.
Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI.Magma (New York, N.Y.) · 2026Article
- Accelerated MRI in temporomandibular joints using AI-assisted compressed sensing technique: a feasibility study.European radiology · 2025Article
- Artificial Intelligence-Assisted Compressed Sensing Technique Accelerates Magnetic Resonance Imaging Simulation for Head and Neck Cancer Radiation Therapy.Advances in radiation oncology · 2025Article
- Free-breathing pediatric cardiac dark-blood imaging with reverse double inversion-recovery and single-shot deep learning reconstruction.Quantitative imaging in medicine and surgery · 2025Article
- Segmentation of hippocampal subregion via 5-Tesla magnetic resonance imaging: a comparative study.Quantitative imaging in medicine and surgery · 2025Article
- AI-assisted compressed sensing MRI improves imaging quality in rectal cancer: a comparative study with conventional acceleration techniques.Quantitative imaging in medicine and surgery · 2025Article
- AI-Assisted Compressed Sensing Enables Faster Brain MRI for the Elderly: Image Quality and Diagnostic Equivalence with Conventional Imaging.International journal of general medicine · 2025Article
- Comparison of different acceleration factors of artificial intelligence-compressed sensing for brachial plexus MRI imaging: scanning time and image quality.BMC medical imaging · 2024Article
- Accelerating brain three-dimensional T2 fluid-attenuated inversion recovery using artificial intelligence-assisted compressed sensing: a comparison study with parallel imaging.Quantitative imaging in medicine and surgery · 2024Article
- Ultrafast deep learning super-resolution single-shot T2-weighted imaging for robust edema visualization in cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic ResonanceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Dark blood T2-weighted (DB-T2W) imaging is widely used to evaluate myocardial edema in myocarditis and inflammatory cardiomyopathy. However, this technique is sensitive to arrhythmia, tachycardia, and cardiac and respiratory motion due to the long scan time with multiple breath-holds. The application of artificial intelligence (AI)-assisted compressed sensing (ACS) has facilitated significant progress in accelerating medical imaging. However, the effect of DB-T2W imaging on ACS has not been elucidated. This study aimed to examine the effects of ACS on the image quality of single-shot and multi-shot DB-T2W imaging of edema. Methods: Thirty-three patients were included in this study and received DB-T2W imaging with ACS, including single-shot acquisition (SS-ACS) and multi-shot acquisition (MS-ACS). The resulting images were compared with those of the conventional multi-shot DB-T2W imaging with parallel imaging (MS-PI). Quantitative assessments of the signal-to-noise ratio (SNR), tissue contrast ratio (CR), and contrast-to-noise ratio (CNR) were performed. Three radiologists independently evaluated the overall image quality, blood nulling, free wall of the left ventricle, free wall of the right ventricle, and interventricular septum using a 5-point Likert scale. Results: The total scan time of the DB-T2W imaging with ACS was significantly reduced compared to the conventional parallel imaging [number of heartbeats (SS-ACS:MS-ACS:MS-PI) =19:63:99; P<0.001]. The SNR Conclusions: The ACS method shortens the scan time of DB-T2W imaging and achieves comparable or even better image quality compared to the PI method. Moreover, DB-T2W imaging using the ACS method can reduce the number of breath-holds to 1 with single-shot acquisition.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials