Evidence map›Paper›PMID 36914717›Full record

ArticleScientific reports2023

Blind spectral unmixing for characterization of plaque composition based on multispectral photoacoustic imaging.

Camilo Cano, Catarina Matos, Amir Gholampour, Marc van Sambeek, Richard Lopata, Min Wu

Full text read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Camilo CanoDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands. c.a.cano.barrera@tue.nl.
Catarina MatosDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.
Amir GholampourDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.
Marc van SambeekDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.
Richard LopataDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.
Min WuDepartment of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To improve the assessment of carotid plaque vulnerability, a comprehensive characterization of their composition is paramount. Multispectral photoacoustic imaging (MSPAI) can provide plaque composition based on their absorption spectra. However, although various spectral unmixing methods have been developed to characterize different tissue constituents, plaque analysis remains a challenge since its composition is highly complex and diverse. In this study, we employed an adapted piecewise convex multiple-model endmember detection method to identify carotid plaque constituents. Additionally, we explore the selection of the imaging wavelengths in linear models by conditioning the coefficient matrix and its synergy with our unmixing approach. We verified our method using plaque mimicking phantoms and performed ex-vivo MSPAI on carotid endarterectomy samples in a spectral range from 500 to 1300 nm to identify the main spectral features of plaque materials for vulnerability assessment. After imaging, the samples were processed for histological analysis to validate the photoacoustic decomposition. Results show that our approach can perform spectral unmixing and classification of highly heterogeneous biological samples without requiring an extensive fluence correction, enabling the identification of relevant components to assess plaque vulnerability.

Indexed as

Photoacoustic TechniquesPlaque, AtheroscleroticCarotid ArteriesDiagnostic ImagingHumansSpectrum Analysis

Identifiers

PMID36914717
PMCPMC10011570

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read11
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.