Evidence map›Paper›PMID 36913377›Full record

ArticlePloS one2023

Comparative evaluation of saliva and nasopharyngeal swab for SARS-CoV-2 detection using RT-qPCR among COVID-19 suspected patients at Jigjiga, Eastern Ethiopia.

Bawlah Tahir, Fitsum Weldegebreal, Firayad Ayele, Desalegn Admassu Ayana

Open access · goldFull text read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Bawlah TahirDepartment of Medical Laboratory Sciences, Jigjiga University, Jigjiga, Ethiopia.
Fitsum WeldegebrealSchool of Medical Laboratory Sciences, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0002-7867-1483
Firayad AyeleSchool of Medical Laboratory Sciences, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0002-3372-3227
Desalegn Admassu AyanaSchool of Medical Laboratory Sciences, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0002-1544-7492
Haramaya University · ETJigjiga University · ET

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNasopharyngeal swab (NPS) remains the recommended sample type for Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) diagnosis. However, the collection procedure causes discomfort and irritation to the patients, lowering the quality of the sample and exposing healthcare workers to risk. Furthermore, there is also a shortage of flocked swabs and personnel protective equipment in low-income settings. Therefore, this necessitates an alternative diagnostic specimen. The purpose of this study was to evaluate the performance of saliva against NPS for SARS-CoV-2 detection using RT-qPCR among COVID-19 suspected patients at Jigjiga, Eastern Ethiopia.

methodsComparative cross-sectional study was conducted from June 28 to July 30, 2022. A total of 227 paired saliva and NPS samples were collected from 227 COVID-19 suspected patients. Saliva and NPS samples were collected and transported to the Somali Regional Molecular Laboratory. Extraction was conducted using DaAn kit (DaAn Gene Co., Ltd China). Veri-Q RT-qPCR was used for amplification and detection (Mico BioMed Co, Ltd, Republic of Korea). The data were entered into Epi-data version 4.6 and analyzed using SPSS 25. McNemar's test was used to compare the detection rate. Agreement between NPS and saliva was performed using Cohen's Kappa. The mean and median of cycle threshold values were compared using paired t-tests and the correlation between cycle threshold values was measured using Pearson correlation coefficient. P value < 0.05 was considered statistically significant.

resultsThe overall positivity rate of SARS-CoV-2 RNA was 22.5% (95% CI 17-28%). Saliva showed higher sensitivity (83.8%, 95% CI, 73-94.5%) than NPS (68.9%, 95% CI 60.8-76.8%). The specificity of saliva was 92.6% (95% CI, 80.6% - 100%) compared to NPS (96.7%, 95% CI, 87% - 100%). The positive, negative, and overall percent agreement between NPS and saliva was 83.8%, 92.6%, and 91.2% respectively (κ = 0.703, 95% CI 0.58-0.825, P = 0.00). The concordance rate between the two samples was 60.8%. NPS showed a higher viral load than saliva. There was low positive correlation between the cycle threshold values of the two samples (r = 0.41, 95% CI -1.69 to -0.98, P >0.05).

conclusionSaliva showed a higher detection rate for SARS-CoV-2 molecular diagnosis than NPS and there was significant agreement between the two specimens. Therefore, saliva could be suitable and easily obtainable alternative diagnostic specimen for SARS-CoV-2 molecular diagnosis.

Indexed as

COVID-19Clinical Laboratory TechniquesCOVID-19 TestingCross-Sectional StudiesEthiopiaHumansNasopharynxRNA, ViralSalivaSARS-CoV-2Specimen HandlingRNA, Viral

Identifiers

PMID36913377
PMCPMC10010556
OpenAlexW4324020333

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read239
identifiers read7
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.