Evidence map›Paper›PMID 36912740›Full record

SynthesisThe Cochrane database of systematic reviews2023

Device-modified trabeculectomy for glaucoma.

Junghyun Park, Thanitsara Rittiphairoj, Xue Wang, Jian-Yu E, Amanda K Bicket

Open access · greenAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.3field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Longitudinal analysis of XEN45 gel stent bleb morphology using bleb grading scales, anterior segment-OCT, in vivo confocal microscopy, and impression cytology.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 2 countries.

Junghyun ParkDepartment of Ophthalmology, Inje University Seoul Paik Hospital, Seoul, Korea, South.
Thanitsara RittiphairojDepartment of Ophthalmology, University of Colorado Denver Anschutz Medical Campus, Aurora, Colorado, USA.
Xue WangDepartment of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA.
Jian-Yu EWilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Amanda K BicketOphthalmology & Visual Sciences, University of Michigan, Ann Arbor, Michigan, USA.
Inje University Seoul Paik Hospital · KRJohns Hopkins Medicine · USJohns Hopkins University · USUniversity of Colorado Anschutz Medical Campus · USUniversity of Michigan–Ann Arbor · US

Funding

Maximizing Use of High-Quality Evidence in Eye Care: Cochrane Eyes and Vision US ProjectUG1EY020522 · NEI · UNIVERSITY OF COLORADO DENVER · PI Tianjing Li · 2017 to 2026
$10.1M
NEI NIH HHS UG1 EY020522
6 · The paper itself

Abstract

backgroundGlaucoma is an optic neuropathy that leads to visual field defects and vision loss. It is the second leading cause of irreversible blindness in the world. Treatment for glaucoma aims to reduce intraocular pressure (IOP) to slow or prevent further vision loss. IOP can be lowered with medications, laser, or incisional surgery. Trabeculectomy is a surgical approach which lowers IOP by shunting aqueous humor to a subconjunctival bleb. Device-modified trabeculectomy techniques are intended to improve the durability and safety of this bleb-forming surgery. Trabeculectomy-modifying devices include the Ex-PRESS, the XEN Gel Stent, the PreserFlo MicroShunt, as well as antifibrotic materials such as Ologen, amniotic membrane, expanded polytetrafluoroethylene (ePTFE) membrane, Gelfilm and others. However, the comparative effectiveness and safety of these devices are uncertain.

objectivesTo evaluate the benefits and harms of different devices as adjuncts to trabeculectomy on IOP control in eyes with glaucoma compared to standard trabeculectomy. SEARCH

methodsWe used standard, extensive Cochrane search methods. The latest search was August 2021. SELECTION CRITERIA: We included randomized controlled trials in participants with glaucoma comparing device-modified trabeculectomy techniques with standard trabeculectomy. We included studies that used antimetabolites in either or both treatment groups. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were 1. change in IOP and 2. mean postoperative IOP at one year. Our secondary outcomes were 3. mean change in IOP from baseline, 4. mean postoperative IOP at any time point, 5. mean best-corrected visual acuity (BCVA), 6. visual field change, 7. quality of life, 8. proportion of participants who are drop-free at one year, 9. mean number of IOP lowering medications at one year, and 10. proportion of participants with complications. MAIN

resultsEight studies met our inclusion criteria, of which seven were full-length journal articles and one was a conference abstract. The eight studies included 961 participants with glaucoma, and compared two types of devices implanted during trabeculectomy versus standard trabeculectomy. Seven studies (462 eyes, 434 participants) used the Ex-PRESS, and one study (527 eyes, 527 participants) used the PreserFlo MicroShunt. No studies using the XEN Gel Stent implantation met our criteria. The studies were conducted in North America, Europe, and Africa. Planned follow-up periods ranged from six months to five years. The studies were reported poorly, which limited our ability to judge risk of bias for many domains. None of the studies explicitly masked outcome assessment. We rated seven studies at high risk of detection bias. Low-certainty of evidence from five studies showed that using the Ex-PRESS plus trabeculectomy compared with standard trabeculectomy may be associated with a slightly lower IOP at one year (mean difference (MD) -1.76 mmHg, 95% confidence interval (CI) -2.81 to -0.70; 213 eyes). Moderate-certainty of evidence from one study showed that using the PreserFlo MicroShunt may be associated with a slightly higher IOP than standard trabeculectomy at one year (MD 3.20 mmHg, 95% CI 2.29 to 4.11). Participants who received standard trabeculectomy may have a higher risk of hypotony compared with those who received device-modified trabeculectomy, but the evidence is uncertain (RR 0.73, 95% CI 0.46 to 1.17; I² = 38%; P = 0.14). In the subgroup of participants who received the PreserFlo MicroShunt, there was a lower risk of developing hypotony or shallow anterior chamber compared with those receiving standard trabeculectomy (RR 0.44, 95% CI 0.25 to 0.79; 526 eyes). Device-modified trabeculectomy may lead to less subsequent cataract surgery within one year (RR 0.46, 95% CI 0.27 to 0.80; I² = 0%). AUTHORS'

conclusionsUse of an Ex-PRESS plus trabeculectomy may produce greater IOP reduction at one-year follow-up than standard trabeculectomy; however, due to potential biases and imprecision in effect estimates, the certainty of evidence is low. PreserFlo MicroShunt may be inferior to standard trabeculectomy in lowering IOP. However, PreserFlo MicroShunt may prevent postoperative hypotony and bleb leakage. Overall, device-modified trabeculectomy appears associated with a lower risk of cataract surgery within five years compared with standard trabeculectomy. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic).

Indexed as

CataractGlaucomaTrabeculectomyHumansIntraocular PressureQuality of LifeRandomized Controlled Trials as Topic

Identifiers

PMID36912740
PMCPMC10010250
OpenAlexW4324017426

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.