Evidence map›Paper›PMID 36905729›Full record

ArticleJournal of biomechanics2023

Multi-sweep 3-dimensional ultrasound is accurate for in vivo muscle volume quantification, expanding use to larger muscles.

Jorie D Budzikowski, Wendy M Murray

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Jorie D BudzikowskiNorthwestern University, United States; Shirley Ryan AbilityLab, United States; Edward Hines, Jr. Veterans Affairs Hospital, United States.
Wendy M MurrayNorthwestern University, United States; Shirley Ryan AbilityLab, United States; Edward Hines, Jr. Veterans Affairs Hospital, United States. Electronic address: w-murray@northwestern.edu.
Edward Hines, Jr. VA Hospital · USShirley Ryan AbilityLab · US

Funding

How Do Wrist Surgical Salvage Procedures Limit Hand Strength?I01RX001990 · VA · EDWARD HINES JR VA HOSPITAL · PI MURRAY, WENDY M · 2016 to 2021
–
Development of Ultrasound Imaging Phantoms Appropriate for Quantification of Muscle Fascicle Architecture and Mechanical PropertiesI21RX003610 · VA · EDWARD HINES JR VA HOSPITAL · PI MURRAY, WENDY M · 2021 to 2022
–
RRD VA I01 RX001990RRD VA I21 RX003610
6 · The paper itself

Abstract

Muscle volume is an important parameter in analyzing three-dimensional structure of muscle-tendon units. Three-dimensional ultrasound (3DUS) enables excellent quantification of muscle volume in small muscles; however, when a muscle's cross sectional area is larger than the field of view of the ultrasound transducer at any point along its length, more than one sweep is necessary to reconstruct muscle anatomy. Confounding image registration errors have been reported between multiple sweeps. Here, we detail imaging phantom studies used to (1) define an acquisition protocol that reduces misalignment in 3D reconstruction caused by muscle deformation, and (2) quantify accuracy of 3DUS for measures of volume when phantoms are too large to be fully imaged via a single transducer sweep. Finally, we (3) establish the feasibility of our protocol for in vivo measures by comparing biceps brachii muscle volumes using 3DUS and magnetic resonance imaging (MRI). Phantom studies indicate operator intent to use constant pressure across multiple sweeps effectively mitigates image misalignment, yielding minimal volume error (1.70 ± 1.30%). Intentional application of different pressure between sweeps replicated discontinuity observed previously, leading to larger errors (5.30 ± 0.94%). Based on these findings, we adopted a gel bag standoff and acquired in vivo images of biceps brachii muscles using 3DUS and compared this volume to MRI. We did not observe misalignment errors and there were no significant differences between imaging modalities (-0.71 ± 5.03 %), indicating 3DUS can reliably be used to quantify muscle volume in larger muscles requiring multiple transducer sweeps.

Indexed as

Imaging, Three-DimensionalMuscle, SkeletalPhantoms, ImagingTendonsUltrasonographyMRIMuscle volumeMusculoskeletal imagingUltrasoundUpper limb

Identifiers

PMID36905729
PMCPMC10081694
OpenAlexW4321486850

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.