ArticleInternational ophthalmology2023
The effects of programmed optical zones on achieved corneal refractive power with myopic astigmatism after small incision lenticule extraction (SMILE): a vector analysis.
Article in International ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
purposeTo evaluate the effects of different programmed optical zones (POZs) on achieved corneal refractive power (CRP) with myopic astigmatism after small incision lenticule extraction (SMILE).
methodsIn total, 113 patients (113 eyes) were included in this retrospective study. The eyes were divided into two groups according to POZ: group A (6.5, 6.6, and 6.7 mm, n = 59) and group B (6.8, 6.9, and 7.0 mm, n = 54). Fourier vector analysis was applied to evaluate the error values between the attempted and achieved corneal refractive power (CRP). Alpins vector analysis was used to calculate surgically induced astigmatism (SIA), difference vector (DV), magnitude of error (ME), and astigmatism correction index (ACI). Multivariate regression analysis was performed to assess potential factors associated with the error values.
resultsThe error values in the group with large POZ were closer to zero, and significantly associated with the POZ at 2 and 4 mm of the cornea (β = - 0.50, 95% confidence interval [CI] [- 0.80, - 0.20]; β = - 0.37, 95% CI [- 0.63, - 0.10], P < 0.05, respectively). For the correction of astigmatism, the values of SIA, ME, and ACI were lower in group B than in group A (P < 0.05). The fitting curves between TIA and SIA were y = 0.83x + 0.19 (R
conclusionsSmaller POZs resulted in higher error values between the achieved- and attempted-CRP in the SMILE procedure, which should be considered when performing surgery.
Indexed as
Identifiers
36905461What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.