Evidence map›Paper›PMID 36905053›Full record

ArticleSensors (Basel, Switzerland)2023

Self-Excited Microcantilever with Higher Mode Using Band-Pass Filter.

Yuji Hyodo, Hiroshi Yabuno

Full text read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yuji HyodoDegrees Programs in Systems and Information Engineering, Graduate School of Science and Technology, University of Tsukuba, Tsukuba 305-8573, Ibaraki, Japan.ORCID 0000-0002-6153-8897
Hiroshi YabunoDegrees Programs in Systems and Information Engineering, Graduate School of Science and Technology, University of Tsukuba, Tsukuba 305-8573, Ibaraki, Japan.ORCID 0000-0002-8200-1597

Funding

Ministry of Education, Culture, Sports, Science and Technology 22H01424
6 · The paper itself

Abstract

Microresonators have a variety of scientific and industrial applications. The measurement methods based on the natural frequency shift of a resonator have been studied for a wide range of applications, including the detection of the microscopic mass and measurements of viscosity and stiffness. A higher natural frequency of the resonator realizes an increase in the sensitivity and a higher-frequency response of the sensors. In the present study, by utilizing the resonance of a higher mode, we propose a method to produce the self-excited oscillation with a higher natural frequency without downsizing the resonator. We establish the feedback control signal for the self-excited oscillation using the band-pass filter so that the signal consists of only the frequency corresponding to the desired excitation mode. It results that careful position setting of the sensor for constructing a feedback signal, which is needed in the method based on the mode shape, is not necessary. By the theoretical analysis of the equations governing the dynamics of the resonator coupled with the band-pass filter, it is clarified that the self-excited oscillation is produced with the second mode. Furthermore, the validity of the proposed method is experimentally confirmed by an apparatus using a microcantilever.

Indexed as

higher modeMEMSmicrocantileverself-excited oscillation

Identifiers

PMID36905053
PMCPMC10006876

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read15
table measurements read11
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.