Evidence map›Paper›PMID 36904919›Full record

ArticleSensors (Basel, Switzerland)2023

Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures.

Mustafa Ur Rehman, Kamran Shah, Izhar Ul Haq, Sajid Iqbal, Mohamed A Ismail, Fatih Selimefendigil

Full text read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mustafa Ur RehmanDepartment of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan.ORCID 0000-0003-0568-3712
Kamran ShahDepartment of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan.
Izhar Ul HaqDepartment of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan.
Sajid IqbalDepartment of Information Systems, King Faisal University, Al-Hofuf 31982, Saudi Arabia.
Mohamed A IsmailDepartment of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia.ORCID 0000-0003-4078-288X
Fatih SelimefendigilDepartment of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia.

Funding

King Faisal University, Saudi Arabia Grant No. 2980
6 · The paper itself

Abstract

Using force myography (FMG) to monitor volumetric changes in limb muscles is a promising and effective alternative for controlling bio-robotic prosthetic devices. In recent years, there has been a focus on developing new methods to improve the performance of FMG technology in the control of bio-robotic devices. This study aimed to design and evaluate a novel low-density FMG (LD-FMG) armband for controlling upper limb prostheses. The study investigated the number of sensors and sampling rate for the newly developed LD-FMG band. The performance of the band was evaluated by detecting nine gestures of the hand, wrist, and forearm at varying elbow and shoulder positions. Six subjects, including both fit and amputated individuals, participated in this study and completed two experimental protocols: static and dynamic. The static protocol measured volumetric changes in forearm muscles at the fixed elbow and shoulder positions. In contrast, the dynamic protocol included continuous motion of the elbow and shoulder joints. The results showed that the number of sensors significantly impacts gesture prediction accuracy, with the best accuracy achieved on the 7-sensor FMG band arrangement. Compared to the number of sensors, the sampling rate had a lower influence on prediction accuracy. Additionally, variations in limb position greatly affect the classification accuracy of gestures. The static protocol shows an accuracy above 90% when considering nine gestures. Among dynamic results, shoulder movement shows the least classification error compared to elbow and elbow-shoulder (ES) movements.

Indexed as

GesturesUpper ExtremityElectromyographyHandHumansMovementMyographyaccuracydynamic protocolforce myography (FMG)gesturesstatic protocol

Identifiers

PMID36904919
PMCPMC10007530

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read36
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.