Evidence map›Paper›PMID 36904905›Full record

ArticleSensors (Basel, Switzerland)2023

Design of Hardware Accelerators for Optimized and Quantized Neural Networks to Detect Atrial Fibrillation in Patch ECG Device with RISC-V.

Ingo Hoyer, Alexander Utz, André Lüdecke, Holger Kappert, Maurice Rohr, Christoph Hoog Antink, Karsten Seidl

Full text read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ingo HoyerFraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany.ORCID 0000-0001-7877-6544
Alexander UtzFraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany.ORCID 0000-0002-1274-4563
André LüdeckeFraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany.ORCID 0000-0001-6464-6773
Holger KappertFraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany.
Maurice RohrKIS*MED (AI Systems in Medicine), Technical University of Darmstadt, 64289 Darmstadt, Germany.ORCID 0000-0002-6053-6558
Christoph Hoog AntinkKIS*MED (AI Systems in Medicine), Technical University of Darmstadt, 64289 Darmstadt, Germany.ORCID 0000-0001-7948-8181
Karsten SeidlFraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany.ORCID 0000-0001-6197-5037

Funding

Federal Ministry of Education and Research 13GW0579D
6 · The paper itself

Abstract

Atrial Fibrillation (AF) is one of the most common heart arrhythmias. It is known to cause up to 15% of all strokes. In current times, modern detection systems for arrhythmias, such as single-use patch electrocardiogram (ECG) devices, have to be energy efficient, small, and affordable. In this work, specialized hardware accelerators were developed. First, an artificial neural network (NN) for the detection of AF was optimized. Special attention was paid to the minimum requirements for the inference on a RISC-V-based microcontroller. Hence, a 32-bit floating-point-based NN was analyzed. To reduce the silicon area needed, the NN was quantized to an 8-bit fixed-point datatype (Q7). Based on this datatype, specialized accelerators were developed. Those accelerators included single-instruction multiple-data (SIMD) hardware as well as accelerators for activation functions such as sigmoid and hyperbolic tangents. To accelerate activation functions that require the e-function as part of their computation (e.g., softmax), an e-function accelerator was implemented in the hardware. To compensate for the losses of quantization, the network was expanded and optimized for run-time and memory requirements. The resulting NN has a 7.5% lower run-time in clock cycles (cc) without the accelerators and 2.2 percentage points (pp) lower accuracy compared to a floating-point-based net, while requiring 65% less memory. With the specialized accelerators, the inference run-time was lowered by 87.2% while the F1-Score decreased by 6.1 pp. Implementing the Q7 accelerators instead of the floating-point unit (FPU), the silicon area needed for the microcontroller in 180 nm-technology is below 1 mm2.

Indexed as

Atrial FibrillationComputersElectrocardiographyHumansNeural Networks, ComputerSiliconSiliconartificial intelligenceatrial fibrillationneural networksquantizationRISC-V

Identifiers

PMID36904905
PMCPMC10007562

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read23
identifiers read1
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.